Highly sensitive lipid detection and localization in atherosclerotic plaque with a dual‐frequency intravascular photoacoustic/ultrasound catheter. Issue 3 (1st June 2020)
- Record Type:
- Journal Article
- Title:
- Highly sensitive lipid detection and localization in atherosclerotic plaque with a dual‐frequency intravascular photoacoustic/ultrasound catheter. Issue 3 (1st June 2020)
- Main Title:
- Highly sensitive lipid detection and localization in atherosclerotic plaque with a dual‐frequency intravascular photoacoustic/ultrasound catheter
- Authors:
- Cao, Yingchun
Alloosh, Mouhamad
Sturek, Michael
Cheng, Ji‐Xin - Abstract:
- Abstract: Intravascular photoacoustic/ultrasound (IVPA/US) is an emerging hybrid imaging modality that provides specific lipid detection and localization, while maintaining co‐registered artery morphology, for diagnosis of vulnerable plaque in cardiovascular disease. However, current IVPA/US approaches based on a single‐element transducer exhibit compromised performance for lipid detection due to the relatively low contrast of lipid absorption and conflicting detection bands for photoacoustic and ultrasound signals. Here, we present a dual‐frequency IVPA/US catheter for highly sensitive detection and precision localization of lipids. The low‐frequency transducer provides enhanced photoacoustic sensitivity, while the high‐frequency transducer maintains state‐of‐the‐art spatial resolution for ultrasound imaging. The boosted capability of IVPA/US imaging enables a multi‐scale analysis of lipid distribution in swine with coronary atherosclerosis. The dual‐frequency IVPA/US catheter has a diameter of 1 mm and flexibility to easily adapt to current catheterization procedures and is a significant step toward clinical diagnosis of vulnerable plaque. Abstract : A dual‐frequency intravascular photoacoustic/ultrasound catheter design is developed and validated for lipid‐rich atherosclerotic plaque detection. By combining low‐frequency transducer for highly‐sensitive lipid detection and high‐frequency transducer for accurate localization in a single catheter with 1 mm diameter, thisAbstract: Intravascular photoacoustic/ultrasound (IVPA/US) is an emerging hybrid imaging modality that provides specific lipid detection and localization, while maintaining co‐registered artery morphology, for diagnosis of vulnerable plaque in cardiovascular disease. However, current IVPA/US approaches based on a single‐element transducer exhibit compromised performance for lipid detection due to the relatively low contrast of lipid absorption and conflicting detection bands for photoacoustic and ultrasound signals. Here, we present a dual‐frequency IVPA/US catheter for highly sensitive detection and precision localization of lipids. The low‐frequency transducer provides enhanced photoacoustic sensitivity, while the high‐frequency transducer maintains state‐of‐the‐art spatial resolution for ultrasound imaging. The boosted capability of IVPA/US imaging enables a multi‐scale analysis of lipid distribution in swine with coronary atherosclerosis. The dual‐frequency IVPA/US catheter has a diameter of 1 mm and flexibility to easily adapt to current catheterization procedures and is a significant step toward clinical diagnosis of vulnerable plaque. Abstract : A dual‐frequency intravascular photoacoustic/ultrasound catheter design is developed and validated for lipid‐rich atherosclerotic plaque detection. By combining low‐frequency transducer for highly‐sensitive lipid detection and high‐frequency transducer for accurate localization in a single catheter with 1 mm diameter, this dual‐frequency catheter design largely improves the performance of intravascular photoacoustic imaging and takes a step forward for the translation of this imaging modality for diagnosis of vulnerable plaque at its early stage. … (more)
- Is Part Of:
- Translational biophotonics. Volume 2:Issue 3(2020)
- Journal:
- Translational biophotonics
- Issue:
- Volume 2:Issue 3(2020)
- Issue Display:
- Volume 2, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 2
- Issue:
- 3
- Issue Sort Value:
- 2020-0002-0003-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-06-01
- Subjects:
- atherosclerotic plaque -- dual‐frequency -- intravascular photoacoustic -- lipid core -- Ossabaw miniature swine
Imaging systems in medicine -- Periodicals
Biosensors -- Optical properties -- Periodicals
Photonics -- Periodicals
Imaging systems in medicine
Photonics
Optics and Photonics
Translational Medical Research
Periodicals
Periodical
621.365 - Journal URLs:
- https://onlinelibrary.wiley.com/loi/26271850 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/tbio.202000004 ↗
- Languages:
- English
- ISSNs:
- 2627-1850
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22038.xml