Physical performance of adaptive axial FOV PET scanners with a sparse detector block rings or a checkerboard configuration. (21st May 2022)
- Record Type:
- Journal Article
- Title:
- Physical performance of adaptive axial FOV PET scanners with a sparse detector block rings or a checkerboard configuration. (21st May 2022)
- Main Title:
- Physical performance of adaptive axial FOV PET scanners with a sparse detector block rings or a checkerboard configuration
- Authors:
- Karakatsanis, Nicolas A
Nehmeh, Mohammad H
Conti, Maurizio
Bal, Girish
González, Antonio J
Nehmeh, Sadek A - Abstract:
- Abstract: Objective. Using Monte-Carlo simulations, we evaluated the physical performance of a hypothetical state-of-the-art clinical PET scanner with adaptive axial field-of-view (AFOV) based on the validated GATE model of the Siemens Biograph Vision TM PET/CT scanner. Approach. Vision consists of 16 compact PET rings, each consisting of 152 mini-blocks of 5 × 5 Lutetium Oxyorthosilicate crystals (3.2 × 3.2 × 20 mm 3 ). The Vision 25.6 cm AFOV was extended by adopting (i) a sparse mini-block ring (SBR) configuration of 49.6 cm AFOV, with all mini-block rings interleaved with 16 mm axial gaps, or (ii) a sparse mini-block checkerboard (SCB) configuration of 51.2 cm AFOV, with all mini-blocks interleaved with gaps of 16 mm (transaxial) × 16 mm (axial) width in checkerboard pattern. For sparse configurations, a 'limited' continuous bed motion (limited-CBM) acquisition was employed to extend AFOVs by 2.9 cm. Spatial resolution, sensitivity, image quality (IQ), NECR and scatter fraction were assessed per NEMA NU2-2012. Main Results. All IQ phantom spheres were distinguishable with all configurations. SBR and SCB percent contrast recovery (% CR) and background variability (% BV) were similar ( p -value > 0.05). Compared to Vision, SBR and SCB %CRs were similar ( p -values > 0.05). However, SBR and SCB %BVs were deteriorated by 30% and 26% respectively ( p -values < 0.05). SBR, SCB and Vision exhibited system sensitivities of 16.6, 16.8, and 15.8 kcps MBq −1, NECRs of 311 kcps @35Abstract: Objective. Using Monte-Carlo simulations, we evaluated the physical performance of a hypothetical state-of-the-art clinical PET scanner with adaptive axial field-of-view (AFOV) based on the validated GATE model of the Siemens Biograph Vision TM PET/CT scanner. Approach. Vision consists of 16 compact PET rings, each consisting of 152 mini-blocks of 5 × 5 Lutetium Oxyorthosilicate crystals (3.2 × 3.2 × 20 mm 3 ). The Vision 25.6 cm AFOV was extended by adopting (i) a sparse mini-block ring (SBR) configuration of 49.6 cm AFOV, with all mini-block rings interleaved with 16 mm axial gaps, or (ii) a sparse mini-block checkerboard (SCB) configuration of 51.2 cm AFOV, with all mini-blocks interleaved with gaps of 16 mm (transaxial) × 16 mm (axial) width in checkerboard pattern. For sparse configurations, a 'limited' continuous bed motion (limited-CBM) acquisition was employed to extend AFOVs by 2.9 cm. Spatial resolution, sensitivity, image quality (IQ), NECR and scatter fraction were assessed per NEMA NU2-2012. Main Results. All IQ phantom spheres were distinguishable with all configurations. SBR and SCB percent contrast recovery (% CR) and background variability (% BV) were similar ( p -value > 0.05). Compared to Vision, SBR and SCB %CRs were similar ( p -values > 0.05). However, SBR and SCB %BVs were deteriorated by 30% and 26% respectively ( p -values < 0.05). SBR, SCB and Vision exhibited system sensitivities of 16.6, 16.8, and 15.8 kcps MBq −1, NECRs of 311 kcps @35 kBq cc −1, 266 kcps @25.8 kBq cc −1, and 260 kcps @27.8 kBq cc −1, and scatter fractions of 31.2%, 32.4%, and 32.6%, respectively. SBR and SCB exhibited a smoother sensitivity reduction and noise enhancement rate from AFOV center to its edges. SBR and SCB attained comparable spatial resolution in all directions ( p -value > 0.05), yet, up to 1.5 mm worse than Vision ( p -values < 0.05). Significance. The proposed sparse configurations may offer a clinically adoptable solution for cost-effective adaptive AFOV PET with either highly-sensitive or long-AFOV acquisitions. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 67:Number 10(2022)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 67:Number 10(2022)
- Issue Display:
- Volume 67, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 67
- Issue:
- 10
- Issue Sort Value:
- 2022-0067-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-21
- Subjects:
- PET -- sparse -- ring -- checkerboard -- long -- axial -- field-of-view
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ac6aa1 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22053.xml