Intra‐fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases. Issue 3 (3rd March 2021)
- Record Type:
- Journal Article
- Title:
- Intra‐fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases. Issue 3 (3rd March 2021)
- Main Title:
- Intra‐fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases
- Authors:
- Komiyama, Riho
Ohira, Shingo
Ueda, Hikari
Kanayama, Naoyuki
Masaoka, Akira
Isono, Masaru
Ueda, Yoshihiro
Miyazaki, Masayoshi
Teshima, Teruki - Abstract:
- Abstract: Purpose: This study investigated the intra‐fractional motion (IM) of patients immobilized using the QFix Encompass Immobilization System during HyperArc (HA) treatment. Method: HA treatment was performed on 89 patients immobilized using the Encompass. The IM during treatment (including megavoltage (MV) registration) was analyzed for six degrees of freedom including three axes of translation (anterior‐posterior, superior‐inferior (SI) and left‐right (LR)) and three axes of rotation (pitch, roll, and yaw). Then, the no corrected IM (IMNC ) was retrospectively simulated (excluding MV registration) in three directions (SI, LR, and yaw). Finally, the correlation between the treatment time and the IM of the 3D vector was assessed. Results: The average IM in terms of the absolute displacement were 0.3 mm (SI), 0.3 mm (LR) and 0.2° (yaw) for Stereotactic radiosurgery (SRS), and 0.3 mm (SI), 0.2 mm (LR), and 0.2° (yaw) for stereotactic radiotherapy (SRT). The absolute maximum values of IM were <1 mm along the SI and LR axes and <1° along the yaw axis. The absolute maximum displacements for IMNC were >1 mm along the SI and LR axes and >1° along the yaw axis. In the correlation between the treatment time and the IM, the r ‐values were −0.025 and 0.027 for SRS and SRT respectively, along the axes of translation. For the axes of rotation, the r ‐values were 0.012 and 0.206 for SRS and SRT, respectively. Conclusion: Encompass provided patient immobilization with adequateAbstract: Purpose: This study investigated the intra‐fractional motion (IM) of patients immobilized using the QFix Encompass Immobilization System during HyperArc (HA) treatment. Method: HA treatment was performed on 89 patients immobilized using the Encompass. The IM during treatment (including megavoltage (MV) registration) was analyzed for six degrees of freedom including three axes of translation (anterior‐posterior, superior‐inferior (SI) and left‐right (LR)) and three axes of rotation (pitch, roll, and yaw). Then, the no corrected IM (IMNC ) was retrospectively simulated (excluding MV registration) in three directions (SI, LR, and yaw). Finally, the correlation between the treatment time and the IM of the 3D vector was assessed. Results: The average IM in terms of the absolute displacement were 0.3 mm (SI), 0.3 mm (LR) and 0.2° (yaw) for Stereotactic radiosurgery (SRS), and 0.3 mm (SI), 0.2 mm (LR), and 0.2° (yaw) for stereotactic radiotherapy (SRT). The absolute maximum values of IM were <1 mm along the SI and LR axes and <1° along the yaw axis. The absolute maximum displacements for IMNC were >1 mm along the SI and LR axes and >1° along the yaw axis. In the correlation between the treatment time and the IM, the r ‐values were −0.025 and 0.027 for SRS and SRT respectively, along the axes of translation. For the axes of rotation, the r ‐values were 0.012 and 0.206 for SRS and SRT, respectively. Conclusion: Encompass provided patient immobilization with adequate accuracy during HA treatment. The absolute maximum displacement IM was less than IMNC along the translational/rotational axes, and no statistically significant relationship between the treatment time and the IM was observed. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 3(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 3(2021)
- Issue Display:
- Volume 22, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2021-0022-0003-0000
- Page Start:
- 254
- Page End:
- 260
- Publication Date:
- 2021-03-03
- Subjects:
- HyperArc -- intra‐fractional patient motion -- QFix EncompassTM immobilization system -- stereotactic radiosurgery -- stereotactic radiotherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13143 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22041.xml