Automatic treatment planning for VMAT‐based total body irradiation using Eclipse scripting. Issue 3 (10th February 2021)
- Record Type:
- Journal Article
- Title:
- Automatic treatment planning for VMAT‐based total body irradiation using Eclipse scripting. Issue 3 (10th February 2021)
- Main Title:
- Automatic treatment planning for VMAT‐based total body irradiation using Eclipse scripting
- Authors:
- Teruel, Jose R.
Taneja, Sameer
Galavis, Paulina E.
Osterman, K. Sunshine
McCarthy, Allison
Malin, Martha
Gerber, Naamit K.
Hitchen, Christine
Barbee, David L. - Abstract:
- Abstract: The purpose of this work is to establish an automated approach for a multiple isocenter volumetric arc therapy (VMAT)‐based TBI treatment planning approach. Five anonymized full‐body CT imaging sets were used. A script was developed to automate and standardize the treatment planning process using the Varian Eclipse v15.6 Scripting API. The script generates two treatment plans: a head‐first VMAT‐based plan for upper body coverage using four isocenters and a total of eight full arcs; and a feet‐first AP/PA plan with three isocenters that covers the lower extremities of the patient. PTV was the entire body cropped 5 mm from the patient surface and extended 3 mm into the lungs and kidneys. Two plans were generated for each case: one to a total dose of 1200 cGy in 8 fractions and a second one to a total dose of 1320 cGy in 8 fractions. Plans were calculated using the AAA algorithm and 6 MV photon energy. One plan was created and delivered to an anthropomorphic phantom containing 12 OSLDs for in‐vivo dose verification. For the plans prescribed to 1200 cGy total dose the following dosimetric results were achieved: median PTV V100% = 94.5%; median PTV D98% = 89.9%; median lungs Dmean = 763 cGy; median left kidney Dmean = 1058 cGy; and median right kidney Dmean = 1051 cGy. For the plans prescribed to 1320 cGy total dose the following dosimetric results were achieved: median PTV V100% = 95.0%; median PTV D98% = 88.7%; median lungs Dmean = 798 cGy; median left kidneyAbstract: The purpose of this work is to establish an automated approach for a multiple isocenter volumetric arc therapy (VMAT)‐based TBI treatment planning approach. Five anonymized full‐body CT imaging sets were used. A script was developed to automate and standardize the treatment planning process using the Varian Eclipse v15.6 Scripting API. The script generates two treatment plans: a head‐first VMAT‐based plan for upper body coverage using four isocenters and a total of eight full arcs; and a feet‐first AP/PA plan with three isocenters that covers the lower extremities of the patient. PTV was the entire body cropped 5 mm from the patient surface and extended 3 mm into the lungs and kidneys. Two plans were generated for each case: one to a total dose of 1200 cGy in 8 fractions and a second one to a total dose of 1320 cGy in 8 fractions. Plans were calculated using the AAA algorithm and 6 MV photon energy. One plan was created and delivered to an anthropomorphic phantom containing 12 OSLDs for in‐vivo dose verification. For the plans prescribed to 1200 cGy total dose the following dosimetric results were achieved: median PTV V100% = 94.5%; median PTV D98% = 89.9%; median lungs Dmean = 763 cGy; median left kidney Dmean = 1058 cGy; and median right kidney Dmean = 1051 cGy. For the plans prescribed to 1320 cGy total dose the following dosimetric results were achieved: median PTV V100% = 95.0%; median PTV D98% = 88.7%; median lungs Dmean = 798 cGy; median left kidney Dmean = 1059 cGy; and median right kidney Dmean = 1064 cGy. Maximum dose objective was met for all cases. The dose deviation between the treatment planning dose and the dose measured by the OSLDs was within ±4%. In summary, we have demonstrated that scripting can produce high‐quality plans based on predefined dose objectives and can decrease planning time by automatic target and optimization contours generation, plan creation, field and isocenter placement, and optimization objectives setup. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 3(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 3(2021)
- Issue Display:
- Volume 22, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2021-0022-0003-0000
- Page Start:
- 119
- Page End:
- 130
- Publication Date:
- 2021-02-10
- Subjects:
- advanced treatment planning -- eclipse scripting -- plan automation -- special procedures -- total body irradiation (TBI)
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13189 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22041.xml