Intensity correction for multichannel hyperpolarized 13C imaging of the heart. Issue 2 (1st December 2015)
- Record Type:
- Journal Article
- Title:
- Intensity correction for multichannel hyperpolarized 13C imaging of the heart. Issue 2 (1st December 2015)
- Main Title:
- Intensity correction for multichannel hyperpolarized 13C imaging of the heart
- Authors:
- Dominguez‐Viqueira, William
Geraghty, Benjamin J.
Lau, Justin Y.C.
Robb, Fraser J.
Chen, Albert P.
Cunningham, Charles H. - Abstract:
- Abstract : Purpose: Develop and test an analytic correction method to correct the signal intensity variation caused by the inhomogeneous reception profile of an eight‐channel phased array for hyperpolarized 13 C imaging. Theory and Methods: Fiducial markers visible in anatomical images were attached to the individual coils to provide three dimensional localization of the receive hardware with respect to the image frame of reference. The coil locations and dimensions were used to numerically model the reception profile using the Biot‐Savart Law. The accuracy of the coil sensitivity estimation was validated with images derived from a homogenous 13 C phantom. Numerical coil sensitivity estimates were used to perform intensity correction of in vivo hyperpolarized 13 C cardiac images in pigs. Results: In comparison to the conventional sum‐of‐squares reconstruction, improved signal uniformity was observed in the corrected images. Conclusion: The analytical intensity correction scheme was shown to improve the uniformity of multichannel image reconstruction in hyperpolarized [1‐ 13 C]pyruvate and 13 C‐bicarbonate cardiac MRI. The method is independent of the pulse sequence used for 13 C data acquisition, simple to implement and does not require additional scan time, making it an attractive technique for multichannel hyperpolarized 13 C MRI. Magn Reson Med 75:859–865, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 2(2016:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 2(2016:Feb.)
- Issue Display:
- Volume 75, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 2
- Issue Sort Value:
- 2016-0075-0002-0000
- Page Start:
- 859
- Page End:
- 865
- Publication Date:
- 2015-12-01
- Subjects:
- Multichannel -- 13C -- hyperpolarization -- metabolism -- pyruvate -- cardiac -- DNP
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26042 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22037.xml