An efficient calculation method for pharmacokinetic parameters in brain permeability study using dynamic contrast‐enhanced MRI. Issue 2 (29th March 2015)
- Record Type:
- Journal Article
- Title:
- An efficient calculation method for pharmacokinetic parameters in brain permeability study using dynamic contrast‐enhanced MRI. Issue 2 (29th March 2015)
- Main Title:
- An efficient calculation method for pharmacokinetic parameters in brain permeability study using dynamic contrast‐enhanced MRI
- Authors:
- Wang, Chunhao
Yin, Fang‐Fang
Chang, Zheng - Abstract:
- Abstract : Purpose: To develop an efficient method for calculating pharmacokinetic (PK) parameters in brain DCE‐MRI permeability studies. Methods: A linear least‐squares fitting algorithm based on a derivative expression of the two‐compartment PK model was proposed to analytically solve for the PK parameters. Noise in the expression was minimized through low‐pass filtering. Simulation studies were conducted in which the proposed method was compared with two existing methods in terms of accuracy and efficiency. Five in vivo brain studies were demonstrated for potential clinical application. Results: In the simulation studies using chosen parameter values, the calculated percent difference of K trans by the proposed method was <5.0% with a temporal resolution (Δ t ) < 5 s, and the accuracies of all parameter results were better or comparable to existing methods. When analyzed within certain parameter intensity ranges, the proposed method was more accurate than the existing methods and improved the efficiency by a factor of up to 458 for a Δ t = 1 s and up to 38 for a Δ t = 5 s. In the in vivo study, the calculated parameters using the proposed method were comparable to those using the existing methods with improved efficiencies. Conclusions: An efficient method was developed for the accurate and efficient calculation of parameters in brain DCE‐MRI permeability studies. Magn Reson Med 75:739–749, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 2(2016:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 2(2016:Feb.)
- Issue Display:
- Volume 75, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 2
- Issue Sort Value:
- 2016-0075-0002-0000
- Page Start:
- 739
- Page End:
- 749
- Publication Date:
- 2015-03-29
- Subjects:
- DCE‐MRI -- permeability parameter calculation -- computation efficiency -- computer simulation
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25659 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22024.xml