Desynchronization of Cartesian k‐space sampling and periodic motion for improved retrospectively self‐gated 3D lung MRI using quasi‐random numbers. Issue 2 (10th March 2016)
- Record Type:
- Journal Article
- Title:
- Desynchronization of Cartesian k‐space sampling and periodic motion for improved retrospectively self‐gated 3D lung MRI using quasi‐random numbers. Issue 2 (10th March 2016)
- Main Title:
- Desynchronization of Cartesian k‐space sampling and periodic motion for improved retrospectively self‐gated 3D lung MRI using quasi‐random numbers
- Authors:
- Weick, Stefan
Völker, Michael
Hemberger, Kathrin
Meyer, Cord
Ehses, Philipp
Polat, Bülent
Breuer, Felix A.
Blaimer, Martin
Fink, Christian
Schad, Lothar R.
Sauer, Otto A.
Flentje, Michael
Jakob, Peter M. - Abstract:
- Abstract : Purpose: To demonstrate that desynchronization between Cartesian k‐space sampling and periodic motion in free‐breathing lung MRI improves the robustness and efficiency of retrospective respiratory self‐gating. Methods: Desynchronization was accomplished by reordering the phase (ky ) and partition (kz ) encoding of a three‐dimensional FLASH sequence according to two‐dimensional, quasi‐random (QR) numbers. For retrospective respiratory self‐gating, the k‐space center signal (DC signal) was acquired separately after each encoded k‐space line. QR sampling results in a uniform distribution of k‐space lines after gating. Missing lines resulting from the gating process were reconstructed using iterative GRAPPA. Volunteer measurements were performed to compare quasi‐random with conventional sampling. Patient measurements were performed to demonstrate the feasibility of QR sampling in a clinical setting. Results: The uniformly sampled k‐space after retrospective gating allows for a more stable iterative GRAPPA reconstruction and improved ghost artifact reduction compared with conventional sampling. It is shown that this stability can either be used to reduce the total scan time or to reconstruct artifact‐free data sets in different respiratory phases, both resulting in an improved efficiency of retrospective respiratory self‐gating. Conclusion: QR sampling leads to desynchronization between repeated data acquisition and periodic respiratory motion. This results in anAbstract : Purpose: To demonstrate that desynchronization between Cartesian k‐space sampling and periodic motion in free‐breathing lung MRI improves the robustness and efficiency of retrospective respiratory self‐gating. Methods: Desynchronization was accomplished by reordering the phase (ky ) and partition (kz ) encoding of a three‐dimensional FLASH sequence according to two‐dimensional, quasi‐random (QR) numbers. For retrospective respiratory self‐gating, the k‐space center signal (DC signal) was acquired separately after each encoded k‐space line. QR sampling results in a uniform distribution of k‐space lines after gating. Missing lines resulting from the gating process were reconstructed using iterative GRAPPA. Volunteer measurements were performed to compare quasi‐random with conventional sampling. Patient measurements were performed to demonstrate the feasibility of QR sampling in a clinical setting. Results: The uniformly sampled k‐space after retrospective gating allows for a more stable iterative GRAPPA reconstruction and improved ghost artifact reduction compared with conventional sampling. It is shown that this stability can either be used to reduce the total scan time or to reconstruct artifact‐free data sets in different respiratory phases, both resulting in an improved efficiency of retrospective respiratory self‐gating. Conclusion: QR sampling leads to desynchronization between repeated data acquisition and periodic respiratory motion. This results in an improved motion artifact reduction in shorter scan time. Magn Reson Med 77:787–793, 2017. © 2016 International Society for Magnetic Resonance in Medicine … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 77:Issue 2(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 77:Issue 2(2017)
- Issue Display:
- Volume 77, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 2
- Issue Sort Value:
- 2017-0077-0002-0000
- Page Start:
- 787
- Page End:
- 793
- Publication Date:
- 2016-03-10
- Subjects:
- lung imaging -- retrospective self‐gating -- quasi‐random sampling -- 4D imaging -- motion artifact reduction
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26159 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22030.xml