Performance of an active fixation bipolar left ventricular lead vs passive fixation quadripolar leads in cardiac resynchronization therapy, a randomized trial. Issue 1 (8th November 2020)
- Record Type:
- Journal Article
- Title:
- Performance of an active fixation bipolar left ventricular lead vs passive fixation quadripolar leads in cardiac resynchronization therapy, a randomized trial. Issue 1 (8th November 2020)
- Main Title:
- Performance of an active fixation bipolar left ventricular lead vs passive fixation quadripolar leads in cardiac resynchronization therapy, a randomized trial
- Authors:
- Keilegavlen, Havard
Schuster, Peter
Hovstad, Thomas
Faerestrand, Svein - Abstract:
- Abstract: Background: Usage of active fixation bipolar left ventricular (LV) leads represents an alternative approach to the more commonly used passive fixation quadripolar leads in cardiac resynchronization therapy (CRT). We compared a bipolar LV lead with a side screw for active fixation and passive fixation quadripolar LV leads. Methods: Sixty‐two patients were before CRT implantations randomly allocated to receive a bipolar (n = 31) or quadripolar (n = 31) LV leads. Speckle‐tracking radial strain echocardiography was used to define the LV segment with latest mechanical activation as the target LV segment. The electrophysiological measurements and the capability to obtain a proximal position in a coronary vein placed over the target segment were assessed. Results: Upon implantation, the quadripolar lead demonstrated a lower pacing capture threshold than the bipolar lead, but at follow‐up, there was no difference. There were no differences in the LV lead implant times or radiation doses. The success rate in reaching the target location was not significantly different between the two LV leads. Conclusions: The pacing capture thresholds were low, with no significant difference between active fixation bipolar leads and quadripolar leads. Active fixation leads did not promote a more proximal location of the stimulating electrode or a higher grade of concordance to the target segment than passive fixation leads. Abstract : An active fixation bipolar left ventricular pacemakerAbstract: Background: Usage of active fixation bipolar left ventricular (LV) leads represents an alternative approach to the more commonly used passive fixation quadripolar leads in cardiac resynchronization therapy (CRT). We compared a bipolar LV lead with a side screw for active fixation and passive fixation quadripolar LV leads. Methods: Sixty‐two patients were before CRT implantations randomly allocated to receive a bipolar (n = 31) or quadripolar (n = 31) LV leads. Speckle‐tracking radial strain echocardiography was used to define the LV segment with latest mechanical activation as the target LV segment. The electrophysiological measurements and the capability to obtain a proximal position in a coronary vein placed over the target segment were assessed. Results: Upon implantation, the quadripolar lead demonstrated a lower pacing capture threshold than the bipolar lead, but at follow‐up, there was no difference. There were no differences in the LV lead implant times or radiation doses. The success rate in reaching the target location was not significantly different between the two LV leads. Conclusions: The pacing capture thresholds were low, with no significant difference between active fixation bipolar leads and quadripolar leads. Active fixation leads did not promote a more proximal location of the stimulating electrode or a higher grade of concordance to the target segment than passive fixation leads. Abstract : An active fixation bipolar left ventricular pacemaker lead was compared to passive fixation quadripolar leads in a randomized trial. There were no differences between the types of leads in pacing capture thresholds, procedure times, or success rate to reach the target location. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 37:Issue 1(2021)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 37:Issue 1(2021)
- Issue Display:
- Volume 37, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2021-0037-0001-0000
- Page Start:
- 212
- Page End:
- 218
- Publication Date:
- 2020-11-08
- Subjects:
- biventricular pacemaker -- cardiac resynchronization therapy -- heart failure
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12450 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22029.xml