Joint blood and cerebrospinal fluid suppression for intracranial vessel wall MRI. Issue 2 (13th March 2015)
- Record Type:
- Journal Article
- Title:
- Joint blood and cerebrospinal fluid suppression for intracranial vessel wall MRI. Issue 2 (13th March 2015)
- Main Title:
- Joint blood and cerebrospinal fluid suppression for intracranial vessel wall MRI
- Authors:
- Wang, Jinnan
Helle, Michael
Zhou, Zechen
Börnert, Peter
Hatsukami, Thomas S
Yuan, Chun - Abstract:
- Abstract : Purpose: To develop and evaluate a joint blood and cerebrospinal fluid (CSF) suppression technique for improved intracranial vessel wall MR imaging. Methods: The Delay Alternating with Nutation for Tailored Excitation (DANTE) prepulse was specifically optimized for CSF suppression to improve vessel wall and CSF contrast. It was evaluated on six patients and three healthy volunteers. CSF suppression efficiency, lumen signal to noise ratio, and wall‐lumen contrast to noise ratio were compared between images with and without DANTE in major intercranial artery segments. Contrast changes in tissues were also compared with evaluate the technique's compatibility with multicontrast imaging techniques. Results: The optimized DANTE images significantly improved intracranial vessel wall characterization on all images. Quantitatively, CSF to wall contrast improved by 28% (DANTE‐VISTA 1.354 ± 0.216 versus VISTA 1.057 ± 0.13; P < 0.001). DANTE also significantly improved wall‐lumen (10.55 ± 3.79 versus 9.34 ± 3.54; P < 0.001) and wall‐CSF (4.62 ± 3.19 versus 0.78 ± 2.30; P < 0.001) contrast‐to‐noise ratios. DANTE prepared images were also found to make only minimal impact on static tissue contrast. Conclusion: DANTE prepared MR imaging can significantly improve contrast between the vessel wall and cerebral spinal fluid in major intracranial arteries, holding a good potential to be combined with multicontrast protocol for intracranial wall imaging. Magn Reson Med 75:831–838,Abstract : Purpose: To develop and evaluate a joint blood and cerebrospinal fluid (CSF) suppression technique for improved intracranial vessel wall MR imaging. Methods: The Delay Alternating with Nutation for Tailored Excitation (DANTE) prepulse was specifically optimized for CSF suppression to improve vessel wall and CSF contrast. It was evaluated on six patients and three healthy volunteers. CSF suppression efficiency, lumen signal to noise ratio, and wall‐lumen contrast to noise ratio were compared between images with and without DANTE in major intercranial artery segments. Contrast changes in tissues were also compared with evaluate the technique's compatibility with multicontrast imaging techniques. Results: The optimized DANTE images significantly improved intracranial vessel wall characterization on all images. Quantitatively, CSF to wall contrast improved by 28% (DANTE‐VISTA 1.354 ± 0.216 versus VISTA 1.057 ± 0.13; P < 0.001). DANTE also significantly improved wall‐lumen (10.55 ± 3.79 versus 9.34 ± 3.54; P < 0.001) and wall‐CSF (4.62 ± 3.19 versus 0.78 ± 2.30; P < 0.001) contrast‐to‐noise ratios. DANTE prepared images were also found to make only minimal impact on static tissue contrast. Conclusion: DANTE prepared MR imaging can significantly improve contrast between the vessel wall and cerebral spinal fluid in major intracranial arteries, holding a good potential to be combined with multicontrast protocol for intracranial wall imaging. Magn Reson Med 75:831–838, 2016. © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 2(2016:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 2(2016:Feb.)
- Issue Display:
- Volume 75, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 2
- Issue Sort Value:
- 2016-0075-0002-0000
- Page Start:
- 831
- Page End:
- 838
- Publication Date:
- 2015-03-13
- Subjects:
- DANTE -- intracranial artery -- vessel wall
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25667 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22024.xml