Software annotation of defibrillator files: Ready for prime time?. (March 2021)
- Record Type:
- Journal Article
- Title:
- Software annotation of defibrillator files: Ready for prime time?. (March 2021)
- Main Title:
- Software annotation of defibrillator files: Ready for prime time?
- Authors:
- Gupta, Vishal
Schmicker, Robert H.
Owens, Pamela
Pierce, Ava E.
Idris, Ahamed H. - Abstract:
- Abstract: Background: High-quality chest compressions are associated with improved outcomes after cardiac arrest. Defibrillators record important information about chest compressions during cardiopulmonary resuscitation (CPR) and can be used in quality-improvement programs. Defibrillator review software can automatically annotate files and measure chest compression metrics. However, evidence is limited regarding the accuracy of such measurements. Objective: To compare chest compression fraction (CCF) and rate measurements made with software annotation vs. manual annotation vs. limited manual annotation of defibrillator files recorded during out-of-hospital cardiac arrest (OHCA) CPR. Methods: This was a retrospective, observational study of 100 patients who had CPR for OHCA. We assessed chest compression bioimpedance waveforms from the time of initial CPR until defibrillator removal. A reviewer revised software annotations in two ways: completely manual annotations and limited manual annotations, which marked the beginning and end of CPR and ROSC, but not chest compressions. Measurements were compared for CCF and rate using intraclass correlation coefficient (ICC) analysis. Results: Case mean rate showed no significant difference between the methods (108.1–108.6 compressions per minute) and ICC was excellent (>0.90). The case mean (±SD) CCF for software, manual, and limited manual annotation was 0.64 ± 0.19, 0.86 ± 0.07, and 0.81 ± 0.10, respectively. The ICC for manual vs.Abstract: Background: High-quality chest compressions are associated with improved outcomes after cardiac arrest. Defibrillators record important information about chest compressions during cardiopulmonary resuscitation (CPR) and can be used in quality-improvement programs. Defibrillator review software can automatically annotate files and measure chest compression metrics. However, evidence is limited regarding the accuracy of such measurements. Objective: To compare chest compression fraction (CCF) and rate measurements made with software annotation vs. manual annotation vs. limited manual annotation of defibrillator files recorded during out-of-hospital cardiac arrest (OHCA) CPR. Methods: This was a retrospective, observational study of 100 patients who had CPR for OHCA. We assessed chest compression bioimpedance waveforms from the time of initial CPR until defibrillator removal. A reviewer revised software annotations in two ways: completely manual annotations and limited manual annotations, which marked the beginning and end of CPR and ROSC, but not chest compressions. Measurements were compared for CCF and rate using intraclass correlation coefficient (ICC) analysis. Results: Case mean rate showed no significant difference between the methods (108.1–108.6 compressions per minute) and ICC was excellent (>0.90). The case mean (±SD) CCF for software, manual, and limited manual annotation was 0.64 ± 0.19, 0.86 ± 0.07, and 0.81 ± 0.10, respectively. The ICC for manual vs. limited manual annotation of CCF was 0.69 while for individual minute epochs it was 0.83. Conclusion: Software annotation performed very well for chest compression rate. For CCF, the difference between manual and software annotation measurements was clinically important, while manual vs. limited manual annotation were similar with an ICC that was good-to-excellent. … (more)
- Is Part Of:
- Resuscitation. Volume 160(2021)
- Journal:
- Resuscitation
- Issue:
- Volume 160(2021)
- Issue Display:
- Volume 160, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 160
- Issue:
- 2021
- Issue Sort Value:
- 2021-0160-2021-0000
- Page Start:
- 7
- Page End:
- 13
- Publication Date:
- 2021-03
- Subjects:
- Cardiopulmonary arrest -- Cardiopulmonary resuscitation -- Chest compressions -- Ventricular fibrillation -- Automatic software
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2020.12.019 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22021.xml