Reproducibility of phase rotation stimulated echo acquisition mode at 3T in schizophrenia: Emphasis on glutamine. Issue 2 (11th March 2015)
- Record Type:
- Journal Article
- Title:
- Reproducibility of phase rotation stimulated echo acquisition mode at 3T in schizophrenia: Emphasis on glutamine. Issue 2 (11th March 2015)
- Main Title:
- Reproducibility of phase rotation stimulated echo acquisition mode at 3T in schizophrenia: Emphasis on glutamine
- Authors:
- Bustillo, Juan R.
Rediske, Nathan
Jones, Thomas
Rowland, Laura M.
Abbott, Christopher
Wijtenburg, S. Andrea - Abstract:
- Abstract : Purpose: To determine the reproducibility and reliability of glutamine (Gln), measured with a very short echo time phase rotation stimulated echo acquisition mode (VTE‐PR STEAM) sequence at 3T, in subjects with schizophrenia. Methods: Seven subjects with schizophrenia were scanned twice with VTE‐PR STEAM in a Siemens 3T TIM Trio scanner with a 32‐channel head coil. Spectroscopic data were collected from two voxels in gray matter, one in the dorsal anterior cingulate and the other in the medial occipital cortex. Reproducibility was assessed using coefficients of variation (CVs) and reliability with standard error of measurement and intraclass correlations (ICCs). Phantoms containing increasing concentrations of Gln in a physiologic solution of other neurometabolites with overlapping resonances were scanned to assess the validity of spectral Gln measurement. Results: Very good reliability and reproducibility for Gln in both regions of interest were supported by CVs of ≤10.0% and ICCs of ≥0.6, respectively. Phantom studies documented a robust correspondence between known Gln concentrations and VTE‐PR STEAM measurements of this metabolite (R 2 = 0.988). Conclusion: The VTE‐PR STEAM approach at 3T permits the longitudinal assessment of Gln and other 1 H MR spectroscopy neurometabolites in a clinically plausible setting. Magn Reson Med 75:498–502, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 2(2016:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 2(2016:Feb.)
- Issue Display:
- Volume 75, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 2
- Issue Sort Value:
- 2016-0075-0002-0000
- Page Start:
- 498
- Page End:
- 502
- Publication Date:
- 2015-03-11
- Subjects:
- glutamine -- glutamate -- spectroscopy -- STEAM -- schizophrenia
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25638 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22024.xml