The use of personal protection equipment does not impair the quality of cardiopulmonary resuscitation: A prospective triple-cross over randomised controlled non-inferiority trial. (March 2021)
- Record Type:
- Journal Article
- Title:
- The use of personal protection equipment does not impair the quality of cardiopulmonary resuscitation: A prospective triple-cross over randomised controlled non-inferiority trial. (March 2021)
- Main Title:
- The use of personal protection equipment does not impair the quality of cardiopulmonary resuscitation
- Authors:
- Kienbacher, Calvin Lukas
Grafeneder, Jürgen
Tscherny, Katharina
Krammel, Mario
Fuhrmann, Verena
Niederer, Maximilian
Neudorfsky, Sabine
Herbich, Klaus
Schreiber, Wolfgang
Herkner, Harald
Roth, Dominik - Abstract:
- Abstract: Aim: Prior studies suggest that the use of personal protective equipment might impair the quality of critical care. We investigated the influence of personal protective equipment on out-of-hospital cardiopulmonary resuscitation. Methods: Randomised controlled non-inferiority triple-crossover study. Forty-eight emergency medical service providers, randomized into teams of two, performed 12 min of basic life support (BLS) on a manikin after climbing 3 flights of stairs. Three scenarios were completed in a randomised order: Without personal protective equipment, with personal protective equipment including a filtering face piece (FFP) 2 mask with valve, and with personal protective equipment including an FFP2 mask without valve. The primary outcome was mean depth of chest compressions with a pre-defined non-inferiority margin of 3.5 mm. Secondary outcomes included other measurements of CPR quality, providers' subjective exhaustion levels, and providers' vital signs, including end-tidal CO2 . Results: Differences regarding the primary outcome were well below the pre-defined non-inferiority margins for both control vs. personal protective equipment without valve (absolute difference 1 mm, 95% CI [−1, 2]) and control vs. personal protective equipment with valve (absolute difference 1 mm, [−0.2, 2]). This was also true for secondary outcomes regarding quality of chest compressions and providers' vital signs including etCO2 . Subjective physical strain after BLS was higherAbstract: Aim: Prior studies suggest that the use of personal protective equipment might impair the quality of critical care. We investigated the influence of personal protective equipment on out-of-hospital cardiopulmonary resuscitation. Methods: Randomised controlled non-inferiority triple-crossover study. Forty-eight emergency medical service providers, randomized into teams of two, performed 12 min of basic life support (BLS) on a manikin after climbing 3 flights of stairs. Three scenarios were completed in a randomised order: Without personal protective equipment, with personal protective equipment including a filtering face piece (FFP) 2 mask with valve, and with personal protective equipment including an FFP2 mask without valve. The primary outcome was mean depth of chest compressions with a pre-defined non-inferiority margin of 3.5 mm. Secondary outcomes included other measurements of CPR quality, providers' subjective exhaustion levels, and providers' vital signs, including end-tidal CO2 . Results: Differences regarding the primary outcome were well below the pre-defined non-inferiority margins for both control vs. personal protective equipment without valve (absolute difference 1 mm, 95% CI [−1, 2]) and control vs. personal protective equipment with valve (absolute difference 1 mm, [−0.2, 2]). This was also true for secondary outcomes regarding quality of chest compressions and providers' vital signs including etCO2 . Subjective physical strain after BLS was higher in the personal protective equipment groups (Borg 4 (SD 3) without valve, 4 (SD 2) with valve) than in the control group (Borg 3 (SD 2)). Conclusion: PPE including masks with and without expiration valve is safe for use without concerns regarding the impairment of CPR quality. … (more)
- Is Part Of:
- Resuscitation. Volume 160(2021)
- Journal:
- Resuscitation
- Issue:
- Volume 160(2021)
- Issue Display:
- Volume 160, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 160
- Issue:
- 2021
- Issue Sort Value:
- 2021-0160-2021-0000
- Page Start:
- 79
- Page End:
- 83
- Publication Date:
- 2021-03
- Subjects:
- BLS basic life support -- EMS emergency medical service -- ERC European Resuscitation Council -- FFP filtering face piece -- PPE personal protective equipment
Emergency medical services -- Cardiopulmonary resuscitation -- Chest compressions -- Personal protective equipment -- COVID-19 -- Manikin -- Simulation
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2021.01.021 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22021.xml