Acute change of cardiac autonomic regulations after thermal and non-thermal pulmonary vein ablation. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Acute change of cardiac autonomic regulations after thermal and non-thermal pulmonary vein ablation. (19th May 2022)
- Main Title:
- Acute change of cardiac autonomic regulations after thermal and non-thermal pulmonary vein ablation
- Authors:
- Stojadinovic, P
Wichterle, D
Peichl, P
Cihak, R
Jansova, H
Nejedlo, V
Haskova, J
Kautzner, J - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Pulmonary vein isolation (PVI) by thermal energy (radiofrequency energy or cryoenergy) results in collateral ganglionic plexi ablation. On the contrary, pulsed electric field (PEF) energy presumably spares neural tissue. Purpose: We investigated and compared the effect of PVI on parasympathetic input into the sinus node (SAN) and AV node (AVN) when four different ablation strategies were used. Methods: A study enrolled 49 patients who underwent PVI in general anesthesia (age: 57 ± 13 years, 71% males). In 17 patients, point-by-point radiofrequency energy delivery by the irritated-tip catheter was used for ablation while 7 patients were ablated using a second-generation cryoballoon catheter. In 7 patients, PEF energy was delivered using a single-shot Farawave catheter while 18 patients were ablated using Sphere9 lattice-tip catheter (Affera, Inc.); both subgroups with manufacturer-specific PEF settings. Before and after PVI, the responsiveness of the SAN and AVN was assessed by extracardiac vagal nerve stimulation (ECVS) via a diagnostic catheter in the right internal jugular vein. Five-second stimulation trains were delivered with a frequency of 50 Hz, pulse width of 0.05 ms, and output of 1 V/kg (<70V) both in sinus rhythm and during atrial pacing. Substantial reduction of response to ECVS was arbitrarily defined as a maximum induced pause of <1.5 seconds. Results: At baseline, physiologicalAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Pulmonary vein isolation (PVI) by thermal energy (radiofrequency energy or cryoenergy) results in collateral ganglionic plexi ablation. On the contrary, pulsed electric field (PEF) energy presumably spares neural tissue. Purpose: We investigated and compared the effect of PVI on parasympathetic input into the sinus node (SAN) and AV node (AVN) when four different ablation strategies were used. Methods: A study enrolled 49 patients who underwent PVI in general anesthesia (age: 57 ± 13 years, 71% males). In 17 patients, point-by-point radiofrequency energy delivery by the irritated-tip catheter was used for ablation while 7 patients were ablated using a second-generation cryoballoon catheter. In 7 patients, PEF energy was delivered using a single-shot Farawave catheter while 18 patients were ablated using Sphere9 lattice-tip catheter (Affera, Inc.); both subgroups with manufacturer-specific PEF settings. Before and after PVI, the responsiveness of the SAN and AVN was assessed by extracardiac vagal nerve stimulation (ECVS) via a diagnostic catheter in the right internal jugular vein. Five-second stimulation trains were delivered with a frequency of 50 Hz, pulse width of 0.05 ms, and output of 1 V/kg (<70V) both in sinus rhythm and during atrial pacing. Substantial reduction of response to ECVS was arbitrarily defined as a maximum induced pause of <1.5 seconds. Results: At baseline, physiological response to ECVS (long sinus arrest and/or AV block) was demonstrated. After PVI, a substantial reduction of SAN response was observed in 21/24 (88%) patients after thermal PVI and 7/25 (25%) patients after non-thermal PVI (P = 0.0001). Similarly, a substantial reduction of AVN response was observed in 21/24 (88%) patients after thermal PVI and 9/25 (36%) patients after non-thermal PVI (P = 0.0003). The Figure shows on the continuous scale the post-PVI pauses in sinus rhythm (maximum P-P interval) and atrial pacing (maximum R-R interval) induced by ECVS. Conclusion: Vagal responses of SAN and AVN are preserved in most AF patients after non-thermal PVI. This contrasts with the much stronger effect of thermal PVI. Whether this may influence the clinical outcome of AF ablation procedures remains to be investigated in future studies. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.232 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22017.xml