Leadless cardiac pacemaker in elderly patients: How old for a new technology?. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Leadless cardiac pacemaker in elderly patients: How old for a new technology?. (19th May 2022)
- Main Title:
- Leadless cardiac pacemaker in elderly patients: How old for a new technology?
- Authors:
- Ben Kilani, M
Carabelli, A
Jacon, P
Venier, S
Peter, P
Deschamps, E
Desbiolles, A
Defaye, P - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Introduction: Leadless transcatheter pacemakers are considered as a safe and effective option for cardiac pacing in patients (pts) at higher risk of complications with conventional transvenous cardiac pacing. Purpose: Our aim was to assess the clinical "real-life" feasibility and outcomes of leadless pacing in elderly pts in a high-volume center over a mid-term follow-up (FU) period. Methods: Elderly pts (aged ≥ 75 years) who underwent leadless MICRA® system pacemaker implantation with a FU period above 3 months were included in this retrospective monocentric study. Results: 130 pts were included (84 ± 5.6 years old, male 66.2%). Indications were: Atrioventricular block (permanent 15.4%; transient 27.7%), atrial fibrillation bradycardia 50% and sinus node dysfunction 6.9%. Leadless system pacing was preferred over conventional pacing in pts with: transvenous pacemaker extractions due to infectious 18.5% or vascular 1.5% complications; active systemic infection and urgent need for cardiac stimulation 20%; complex conventional vascular approach 21.6%; severe tricuspid valve disease 1.5%; deterioration of general condition and clinical frailty 22.3%; shortly after transvalvular aortic valve replacement 8.5%. Among the pts, 6.2% had previous leadless Nanostim® device implantation with dysfunction of the system. Pts had either local anesthesia 13.2% or deep sedation 86.8%. The average fluoroscopy time was 4.3±2.9Abstract: Funding Acknowledgements: Type of funding sources: None. Introduction: Leadless transcatheter pacemakers are considered as a safe and effective option for cardiac pacing in patients (pts) at higher risk of complications with conventional transvenous cardiac pacing. Purpose: Our aim was to assess the clinical "real-life" feasibility and outcomes of leadless pacing in elderly pts in a high-volume center over a mid-term follow-up (FU) period. Methods: Elderly pts (aged ≥ 75 years) who underwent leadless MICRA® system pacemaker implantation with a FU period above 3 months were included in this retrospective monocentric study. Results: 130 pts were included (84 ± 5.6 years old, male 66.2%). Indications were: Atrioventricular block (permanent 15.4%; transient 27.7%), atrial fibrillation bradycardia 50% and sinus node dysfunction 6.9%. Leadless system pacing was preferred over conventional pacing in pts with: transvenous pacemaker extractions due to infectious 18.5% or vascular 1.5% complications; active systemic infection and urgent need for cardiac stimulation 20%; complex conventional vascular approach 21.6%; severe tricuspid valve disease 1.5%; deterioration of general condition and clinical frailty 22.3%; shortly after transvalvular aortic valve replacement 8.5%. Among the pts, 6.2% had previous leadless Nanostim® device implantation with dysfunction of the system. Pts had either local anesthesia 13.2% or deep sedation 86.8%. The average fluoroscopy time was 4.3±2.9 minutes and number of device deployments before the final position ranged from 1 to 7 with a mean value of 1.5±1 positions. Pacing threshold during implant was 0.5±0.4 V at 0.24ms, only 4 pts (3%) had an implant threshold of >1.0 V at 0.24 ms. Two postoperative deaths were observed: 1 cardiac arrest related to myocardial dysfunction and consequent pulmonary edema in a patient with advanced heart failure, and 1 death secondary to myocardial perforation with need for surgical repair that occurred among the first implantations with an apical device position and a patient with multiple comorbidities. The total rate of major complications was 2.3% with only 1 vascular complication at the femoral puncture site. The median time from the leadless pacemaker implant procedure to discharge was 5±6.5 days (minimum 1 and maximum 40 days): 55.6% pts were able to leave the cardiology department within the first 72 hours. The mean FU period was 17 months ± 15 months with a mortality rate of 12.3% (cardiovascular impairment 5.4%; non cardiovascular-related deaths 6.9%). Increase in pacing thresholds was noted in 4 pts with subsequent stabilization; 92.2% of pts presented with thresholds lower than 1V at 0.24 ms. All pts remained free of infections during FU with no cases of device dislodgement observed. Conclusion: Elderly pts are at higher risk of complications; our experience confirms their clinical frailty and underlines the favorable safety profile of leadless system pacing with a low rate of complications and stable pacing thresholds. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.416 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22017.xml