How to better identify patients at high risk of inappropriate shocks before S-ICD implantation: Results from a multicenter experience. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- How to better identify patients at high risk of inappropriate shocks before S-ICD implantation: Results from a multicenter experience. (19th May 2022)
- Main Title:
- How to better identify patients at high risk of inappropriate shocks before S-ICD implantation: Results from a multicenter experience
- Authors:
- Ben Kilani, M
Jacon, P
Badenco, N
Marquie, C
Ollitrault, P
Behar, N
Khattar, P
Carabelli, A
Venier, S
Defaye, P - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Introduction: Despite the recent improvements, inappropriate shocks (IAS) in patients implanted with subcutaneous implantable cardioverter-defibrillator (S-ICD) remain a challenge in "real-life" practice. The purpose of this study was to assess the preoperative predictive factors of IAS with the latest generation of S-ICD, with a particular focus on data obtained during the screening procedure. Methods: Between January 2017 and March 2020, 300 patients implanted with Generation 3 S-ICD system for primary and secondary prevention were included in this multicentric study. Follow-up (FU) of at least 6 months and preoperative screening procedure data were mandatory for all patients. Results: After a mean follow-up of 22.8 (±11.4) months, appropriate therapies occurred in 12.3% patients; while 26 patients (8.7%) experienced inappropriate therapies (incidence 4.9 per 100 patient-years). The total number of inappropriate shock episodes was 48; 9 patients experienced multiple episodes. Causes of IAS were: supraventricular arrhythmias (34.6%), cardiac (30.7%) and extra-cardiac noise oversensing (38.4%). In univariate analysis, availability of all 3 sensing vectors during preoperative screening significantly reduced inappropriate therapies occurrence (hazard ratio [HR], 0.32; 95% confidence interval [CI], 0.12-0.89, P=0.028). Clinical preoperative S-ICD inappropriate shocks predictors were: history of SupraventricularAbstract: Funding Acknowledgements: Type of funding sources: None. Introduction: Despite the recent improvements, inappropriate shocks (IAS) in patients implanted with subcutaneous implantable cardioverter-defibrillator (S-ICD) remain a challenge in "real-life" practice. The purpose of this study was to assess the preoperative predictive factors of IAS with the latest generation of S-ICD, with a particular focus on data obtained during the screening procedure. Methods: Between January 2017 and March 2020, 300 patients implanted with Generation 3 S-ICD system for primary and secondary prevention were included in this multicentric study. Follow-up (FU) of at least 6 months and preoperative screening procedure data were mandatory for all patients. Results: After a mean follow-up of 22.8 (±11.4) months, appropriate therapies occurred in 12.3% patients; while 26 patients (8.7%) experienced inappropriate therapies (incidence 4.9 per 100 patient-years). The total number of inappropriate shock episodes was 48; 9 patients experienced multiple episodes. Causes of IAS were: supraventricular arrhythmias (34.6%), cardiac (30.7%) and extra-cardiac noise oversensing (38.4%). In univariate analysis, availability of all 3 sensing vectors during preoperative screening significantly reduced inappropriate therapies occurrence (hazard ratio [HR], 0.32; 95% confidence interval [CI], 0.12-0.89, P=0.028). Clinical preoperative S-ICD inappropriate shocks predictors were: history of Supraventricular Tachycardia (SVT)(HR, 4.42; 95% CI, 1.45-13.47; P=0.009); overweight (BMI>25: HR, 1.93; 95% CI, 0.83-0.4.48; P=0.13); QRS duration (HR, 1.01; 95% CI, 0.1-1.03; P=0.14) and lower QRS/T wave ratio in lead I (for a threshold < 3: HR, 4.44; 95% CI, 1.88-10.48; P=0.001). By multivariate analysis, independent factors associated with IAS were: the availability of less than 3 sensing vectors during preoperative screening (p<0.05), a low QRS/T wave ratio in lead I (for a threshold <3; p<0.001), history of SVT (p<0.001) and overweight (BMI> 25; p<0.05). Conclusion: Automatic preoperative screening data is of high interest as a predictor of IAS with a quantitative value. ECG specificities in association with other clinical factors should be taken into consideration to identify patients at high risk for IAS. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.464 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22017.xml