Bipolar catheter ablation for highly refractory cardiac arrhythmia - does the success rate depend on arrhythmia origin?. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Bipolar catheter ablation for highly refractory cardiac arrhythmia - does the success rate depend on arrhythmia origin?. (19th May 2022)
- Main Title:
- Bipolar catheter ablation for highly refractory cardiac arrhythmia - does the success rate depend on arrhythmia origin?
- Authors:
- Gardziejczyk, P
Piotrowski, R
Krynski, T
Sikorska, A
Kulakowski, P
Baran, J - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background/Introduction: Despite technological progress, some arrhythmias are still refractory to standard unipolar ablation. They include arrhythmias arising from left ventricular (LV) summit, cardiac crux or epicardium. Bipolar ablation may be useful in some cases, however, data on efficacy of this approach in various arrhythmia localisatons are scarse. Purpose: Aim of the study was to assess efficacy of bipolar catheter ablation in patients with cardiac arrhythmias refractory to standard ablation approach. Methods: Observational, single-center study was conducted over 30-month period. Twenty-six consecutive patients (male=18, aged = 54.26 ± 16.4) who were referred for bipolar ablation were included. All patients had a history of previously failed unipolar ablation procedures. Bipolar ablations were performed using dedicated RF generator and electroanatomic mapping system. Results: Twenty-seven procedures in 26 patients with a mean of 2.52 ± 0.83 previously failed unipolar ablations were included in the final analysis. There were 4 ablations of accessory pathways (3 postero-septal and 1 left free wall) with acute success rate of 100%, 11 procedures of ventricular arrhythmias originating from crux of the heart with acute success rate of 73% and 12 from left ventricular summit (LV summit) with acute success rate of 50%. Mid-term success rate (median follow-up of 182 days) was 100%, 63% and 50% respectively.Abstract: Funding Acknowledgements: Type of funding sources: None. Background/Introduction: Despite technological progress, some arrhythmias are still refractory to standard unipolar ablation. They include arrhythmias arising from left ventricular (LV) summit, cardiac crux or epicardium. Bipolar ablation may be useful in some cases, however, data on efficacy of this approach in various arrhythmia localisatons are scarse. Purpose: Aim of the study was to assess efficacy of bipolar catheter ablation in patients with cardiac arrhythmias refractory to standard ablation approach. Methods: Observational, single-center study was conducted over 30-month period. Twenty-six consecutive patients (male=18, aged = 54.26 ± 16.4) who were referred for bipolar ablation were included. All patients had a history of previously failed unipolar ablation procedures. Bipolar ablations were performed using dedicated RF generator and electroanatomic mapping system. Results: Twenty-seven procedures in 26 patients with a mean of 2.52 ± 0.83 previously failed unipolar ablations were included in the final analysis. There were 4 ablations of accessory pathways (3 postero-septal and 1 left free wall) with acute success rate of 100%, 11 procedures of ventricular arrhythmias originating from crux of the heart with acute success rate of 73% and 12 from left ventricular summit (LV summit) with acute success rate of 50%. Mid-term success rate (median follow-up of 182 days) was 100%, 63% and 50% respectively. There was one major complication (not related to RF bipolar ablation): cardiac tamponade due to aortic cusp rupture requiring urgent cardiac surgery procedure. Conclusions: Bipolar ablation is a promising method of catheter ablation for refractory arrhythmias. The highest success rate was observed in ablation for difficult pathways, followed by ventricular arrhythmias originating from cardiac crux and LV summit. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.060 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml