Accuracy of noninvasive electrocardiographic imaging using isopotential versus isochronal map for identifying the site of origin of ventricular arrhythmias. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Accuracy of noninvasive electrocardiographic imaging using isopotential versus isochronal map for identifying the site of origin of ventricular arrhythmias. (19th May 2022)
- Main Title:
- Accuracy of noninvasive electrocardiographic imaging using isopotential versus isochronal map for identifying the site of origin of ventricular arrhythmias
- Authors:
- Parreira, A
Carmo, P
Marinheiro, R
Chambel, D
Marinescu, C
Ferreira, A
Marques, L
Nunes, S
Chmelevsky, M
Amador, P
Coelho, R
Cavaco, D
Goncalves, P
Marques, H
Adragao, P - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: Private hospital(s). Main funding source(s): Learning Health Background and aim: Previous studies reporting the results of noninvasive electrocardiographic imaging (ECGI) used both isopotential map and isochronal map to assess the site of origin (SOO) of premature ventricular contractions (PVCs). The aim of this study was to evaluate the accuracy of both methods globally, and according to the location of the arrhythmia: from the right ventricular outflow tract (RVOT) or other locations (non-RVOT). Methods: We studied with ECGI 35 consecutive patients with frequent (>10.000/24 h) PVCs. Patients were excluded if the ablation was not performed (7 patients) or was unsuccessful (7 patients). The study group consisted of 21 patients, 11 male, median age of 56 (44-71) years. The ECGI was performed with the epi-endocardial system Amycard. Two noninvasive maps were obtained: isopotential map based on the analysis of the shape and amplitude of the unipolar electrogram (FND method) and an isochronal map obtained using the activation direction method (ADM) (Figure). The invasive activation map was obtained with the Carto or the Ensite system and radiofrequency was applied at the earliest activation site with QS morphology on the unipolar electrogram and a pace match of at least 11/12. The SOO of the PVCs was considered the site where the PVCs were abolished. We assessed the accuracy of the ECGI to identify the SOO of the PVCsAbstract: Funding Acknowledgements: Type of funding sources: Private hospital(s). Main funding source(s): Learning Health Background and aim: Previous studies reporting the results of noninvasive electrocardiographic imaging (ECGI) used both isopotential map and isochronal map to assess the site of origin (SOO) of premature ventricular contractions (PVCs). The aim of this study was to evaluate the accuracy of both methods globally, and according to the location of the arrhythmia: from the right ventricular outflow tract (RVOT) or other locations (non-RVOT). Methods: We studied with ECGI 35 consecutive patients with frequent (>10.000/24 h) PVCs. Patients were excluded if the ablation was not performed (7 patients) or was unsuccessful (7 patients). The study group consisted of 21 patients, 11 male, median age of 56 (44-71) years. The ECGI was performed with the epi-endocardial system Amycard. Two noninvasive maps were obtained: isopotential map based on the analysis of the shape and amplitude of the unipolar electrogram (FND method) and an isochronal map obtained using the activation direction method (ADM) (Figure). The invasive activation map was obtained with the Carto or the Ensite system and radiofrequency was applied at the earliest activation site with QS morphology on the unipolar electrogram and a pace match of at least 11/12. The SOO of the PVCs was considered the site where the PVCs were abolished. We assessed the accuracy of the ECGI to identify the SOO of the PVCs using both methods. A perfect match was defined as a predicted location by the ECGI within the same anatomic segment of the actual SOO of the PVCs, whereas a near match as a predicted location within the same segment or a contiguous one. Values are presented as median (Q1-Q3) Results: PVCs originated in the RVOT in 11 (52%) patients. The percentage of near matches was not significantly different between FND and ADM methods (95% vs 86%, p=0.50), however the percentage of perfect matches was significantly higher with the FND than with the ADM technique (95% vs 67 %, p=0.031). We found no significant differences in accuracy according to the location of the PVCs, in the RVOT or outside (Table). Conclusions: We found a good agreement between ECGI and invasive maps, however the FND technique showed a better accuracy regardless the site of the PVCs. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.023 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml