Procedural and outcome impact of obesity in cryoballoon versus radiofrequency pulmonary vein isolation in atrial fibrillation patients. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Procedural and outcome impact of obesity in cryoballoon versus radiofrequency pulmonary vein isolation in atrial fibrillation patients. (19th May 2022)
- Main Title:
- Procedural and outcome impact of obesity in cryoballoon versus radiofrequency pulmonary vein isolation in atrial fibrillation patients
- Authors:
- Scheurlen, C
Van Den Bruck, JH
Dittrich, S
Erlhoefer, S
Filipovic, K
Lueker, J
Woermann, J
Steven, D
Sultan, A - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Cryoballoon-(CB)- and radiofrequency-(RF)-ablation are the most common techniques for pulmonary vein isolation (PVI) in patients (pts) with symptomatic atrial fibrillation (AF). An increasing number of pts undergoing PVI are obese. Objective: To address the paucity of procedural differences and outcome data of CB- vs. RF-based PVI in relation to body mass index (BMI) of AF patients. Methods: All pts undergoing de novo PVI between 01/2018-08/2019 at our university hospital were included in this retrospective analysis. Pts of each group (CB-PVI vs. RF-PVI) were subdivided based on their BMI: normal weight BMI <25kg/m², pre-obesity 25-30kg/m², obesity stage I 30-35kg/m² and severe obesity stage II ≥35kg/m². Hereafter, procedural characteristics and AF recurrence rate during follow-up were compared with regard the different BMI groups. Results: A total of 526 pts (62% male, 65.3±11.2 years) underwent successful de novo PVI (320 CB and 206 RF). Especially in obese patients, differences in procedural characteristics were noted: A significantly increased contrast medium volume in CB group (all: CB 50 [40-80] vs. RF 20 [20-30], p<0.001; BMI≥35: CB 70 [54.5-102.5] ml vs. RF 20 [15-30] ml, p<0.001). In line with previous studies, the overall procedure time was significantly shorter with CB-PVI (CB 75 [60-100] vs. RF 120 [110-180], p<0.001). Also, as expected, lower fluoroscopy dose was detected in RF groupAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Cryoballoon-(CB)- and radiofrequency-(RF)-ablation are the most common techniques for pulmonary vein isolation (PVI) in patients (pts) with symptomatic atrial fibrillation (AF). An increasing number of pts undergoing PVI are obese. Objective: To address the paucity of procedural differences and outcome data of CB- vs. RF-based PVI in relation to body mass index (BMI) of AF patients. Methods: All pts undergoing de novo PVI between 01/2018-08/2019 at our university hospital were included in this retrospective analysis. Pts of each group (CB-PVI vs. RF-PVI) were subdivided based on their BMI: normal weight BMI <25kg/m², pre-obesity 25-30kg/m², obesity stage I 30-35kg/m² and severe obesity stage II ≥35kg/m². Hereafter, procedural characteristics and AF recurrence rate during follow-up were compared with regard the different BMI groups. Results: A total of 526 pts (62% male, 65.3±11.2 years) underwent successful de novo PVI (320 CB and 206 RF). Especially in obese patients, differences in procedural characteristics were noted: A significantly increased contrast medium volume in CB group (all: CB 50 [40-80] vs. RF 20 [20-30], p<0.001; BMI≥35: CB 70 [54.5-102.5] ml vs. RF 20 [15-30] ml, p<0.001). In line with previous studies, the overall procedure time was significantly shorter with CB-PVI (CB 75 [60-100] vs. RF 120 [110-180], p<0.001). Also, as expected, lower fluoroscopy dose was detected in RF group (all: CB 392.4 [197.9-995.9] vs. RF 282.5 [139.8-507.2], p<0.001). The complication rate was equal throughout all BMI groups. A 12-month follow up was available in 480 of 526 (91%) pts. Freedom from any arrhythmia was comparable between CB-PVI and RF-PVI (CB 77% vs. RF 75%, p=0.63). However, for obese pts a trend towards higher AF recurrence rate after RF- compared to CB-PVI was observed (BMI≥35: CB 24% vs. RF 50%, p=0.099). Conclusion: For obese pts CB-PVI is similarly safe and effective as RF-PVI. The significantly shorter procedure time for CB-PVI may minimize potential obesity-related complications. However, the lower contrast medium quantity and fluoroscopy dose in RF-PVI must be considered. AF recurrence rates were comparable between CB-PVI und RF-PVI. Randomised trials are needed to evaluate the long-term freedom of AF recurrence in pts with higher BMI comparing CB- vs. RF-based PVI and possible obesity related complication. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.211 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml