Short-term electrocardiographic atrial remodelling after asd closure with the gco device in a pediatric population. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Short-term electrocardiographic atrial remodelling after asd closure with the gco device in a pediatric population. (19th May 2022)
- Main Title:
- Short-term electrocardiographic atrial remodelling after asd closure with the gco device in a pediatric population
- Authors:
- Fumanelli, J
Garibaldi, S
Castaldi, B
Di Candia, A
Cuman, M
Pizzuto, A
Sirico, D
Mirizzi, G
Piacenti, M
Cantinotti, M
Assanta, N
Di Salvo, G
Santoro, G - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background and Aim: The GORE® CARDIOFORM septal occluder (GCO) is an atrial septal defect/patent foramen ovale (ASD/PFO) closure device with theoretical advantages over other commercialized devices thanks to its softness and anatomical compliance. Our aim was to evaluate the short and medium-term electrocardiographic changes after percutaneous ASD closure with GCO in a pediatric population. Methods: We enrolled 39 patients with isolated ASD submitted to trans-catheter closure with GCO from January 2020 to June 2021. EKG was performed before (T0), at 24 hours (T1) and 6 months (T2) after ASD transcatheter closure. P wave dispersion was calculated as the difference between maximum and minimum P- wave duration, PR interval as the interval between beginning of the P wave and beginning of the QRS complex and QT dispersion as the difference between maximun and minimun of QTc intervals. At 6-months from device implantation, the patients were submitted to ambulatory EKG Holter recording. Results: Patients' age and BSA were 8.2±4.2 years (IQR 4.2-8.3, median 7.0) and 1.0±0.3 m2 (IQR 0.7-1.7, median 0.9), respectively. The strectched ASD diameter was 16.3±4.5 mm (median 16), resulting in QP/QS of 1.7±0.6 (median 1.5). At the baseline mean P wave dispersion was 40±15 msec and decreased to 30±13 msec (p<0.002) at 24h, without any further change at 6 months (30±13 msec, p<0.002). PR conduction significantly improved at 24Abstract: Funding Acknowledgements: Type of funding sources: None. Background and Aim: The GORE® CARDIOFORM septal occluder (GCO) is an atrial septal defect/patent foramen ovale (ASD/PFO) closure device with theoretical advantages over other commercialized devices thanks to its softness and anatomical compliance. Our aim was to evaluate the short and medium-term electrocardiographic changes after percutaneous ASD closure with GCO in a pediatric population. Methods: We enrolled 39 patients with isolated ASD submitted to trans-catheter closure with GCO from January 2020 to June 2021. EKG was performed before (T0), at 24 hours (T1) and 6 months (T2) after ASD transcatheter closure. P wave dispersion was calculated as the difference between maximum and minimum P- wave duration, PR interval as the interval between beginning of the P wave and beginning of the QRS complex and QT dispersion as the difference between maximun and minimun of QTc intervals. At 6-months from device implantation, the patients were submitted to ambulatory EKG Holter recording. Results: Patients' age and BSA were 8.2±4.2 years (IQR 4.2-8.3, median 7.0) and 1.0±0.3 m2 (IQR 0.7-1.7, median 0.9), respectively. The strectched ASD diameter was 16.3±4.5 mm (median 16), resulting in QP/QS of 1.7±0.6 (median 1.5). At the baseline mean P wave dispersion was 40±15 msec and decreased to 30±13 msec (p<0.002) at 24h, without any further change at 6 months (30±13 msec, p<0.002). PR conduction significantly improved at 24 h from device implantation (from 175.0±20.8 to 144.0±22.7 msec, p=0.018) and did not significantly change at 6 months (164.0±19.5 msec, p=NS). QTc dispersion decreased at 24 hours (31.7±.20.3, p<0.02) and at 6 months (28.0±18.1, p<0.002) from device implantation. After device deployment, 2 pts (5%) developed transient, self-limited junctional rhythm and one of them needed a short course of anti-arrhythmic therapy for supra-ventricular tachycardia. No tachy/brady-arrhythmias were recorded at the 6-months follow-up EKG Holter monitoring. Conclusions: Percutaneous ASD closure with the GCO device results in significant, sudden improvement of intra-atrial, atrio-ventricular and intraventricular electrical homogeneity. This benefit persists unaltered over a medium term follow-up. It might be due to a favourable volumetric remodelling that was not hindered by mechanical impact of the occluding prosthesis and could explain the low rate of arrhythmias found at the mid-term EKG evaluation. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.027 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml