Correlation of local impedance, global impedance and contact force with resulting lesion size in RF ablation. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Correlation of local impedance, global impedance and contact force with resulting lesion size in RF ablation. (19th May 2022)
- Main Title:
- Correlation of local impedance, global impedance and contact force with resulting lesion size in RF ablation
- Authors:
- Wachter, A
Bahlke, F
Popa, M
Foerschner, L
Krafft, H
Maurer, S
Telishevska, M
Englert, F
Lengauer, S
Kottmaier, M
Lennerz, C
Reents, T
Hessling, G
Deisenhofer, I
Bourier, F - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: During clinical application of RF-energy, several parameters are constantly observed, e.g. RF time, power, global impedance and temperature. The new parameter "local impedance" is gaining importance and might be a possible real-time marker for predicting long-lasting RF-lesions and increasing safety. The aim of this study was to investigate the correlation between local and global impedance as well as RF power and contact force. Methods: RF-lesions were created using an ex vivo model with porcine cardiac preparations. These were put in a saline-filled container with a dispersive electrode. Global impedance was held at 120 Ohm by adjusting saline and water. Additionally, a heated thermostat and a circulation pump were installed to imitate blood flow. RF-lesions were produced with different settings of energy and contact force (20, 30, 40 and 50 watts; contact force of 0-5g, 10-15g and 20-25g). While creating the lesions, global and local impedance, temperature, energy and RF time were documented, as well as the current lesion width and depth. Local and global impedance drops were calculated as the difference between baseline impedance and current impedance. Results: In total, 1223 measurements were made during application of RF-energy. 6 steam pops occurred. Contact force, local and global impedance changes showed highly significant correlations with lesion depth and diameter. Amongst analyzedAbstract: Funding Acknowledgements: Type of funding sources: None. Background: During clinical application of RF-energy, several parameters are constantly observed, e.g. RF time, power, global impedance and temperature. The new parameter "local impedance" is gaining importance and might be a possible real-time marker for predicting long-lasting RF-lesions and increasing safety. The aim of this study was to investigate the correlation between local and global impedance as well as RF power and contact force. Methods: RF-lesions were created using an ex vivo model with porcine cardiac preparations. These were put in a saline-filled container with a dispersive electrode. Global impedance was held at 120 Ohm by adjusting saline and water. Additionally, a heated thermostat and a circulation pump were installed to imitate blood flow. RF-lesions were produced with different settings of energy and contact force (20, 30, 40 and 50 watts; contact force of 0-5g, 10-15g and 20-25g). While creating the lesions, global and local impedance, temperature, energy and RF time were documented, as well as the current lesion width and depth. Local and global impedance drops were calculated as the difference between baseline impedance and current impedance. Results: In total, 1223 measurements were made during application of RF-energy. 6 steam pops occurred. Contact force, local and global impedance changes showed highly significant correlations with lesion depth and diameter. Amongst analyzed values, local impedance drop showed highest correlation with lesion diameter and depth (r = 0, 391 and 0, 613; p<0, 001). Visualized in Figure 1 and 2, global and local impedance correlate with lesion diameter and depth. Discussion: Local impedance was found to be a suitable real-time marker for lesion size, showing significantly higher correlations with RF lesion size than contact force and global impedance. Further investigation is necessary to find a cut off for a safe but long-lasting RF-lesion. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.108 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml