Very high-power short-duration temperature-controlled ablation for cavotricuspid isthmus block : the Fast-and-Furious CTI study. (19th May 2022)
- Record Type:
- Journal Article
- Title:
- Very high-power short-duration temperature-controlled ablation for cavotricuspid isthmus block : the Fast-and-Furious CTI study. (19th May 2022)
- Main Title:
- Very high-power short-duration temperature-controlled ablation for cavotricuspid isthmus block : the Fast-and-Furious CTI study
- Authors:
- Kirstein, B
Vogler, J
Eitel, C
Phan, L
Feher, M
Keelani, A
Traub, A
D' Ambrosio, G
Grosse, N
Reincke, S
Hatahet, S
Trajanoski, D
Kuck, K
Tilz, R
Heeger, C - Abstract:
- Abstract: Funding Acknowledgements: Type of funding sources: None. Background: Catheter ablation for typical right atrial flutter (AFL) provides an effective treatment associated with encouraging clinical outcome. The novel micro-electrode ablation catheter allows very high-power short-duration (vHP-SD, 90 W/4 sec) ablation and potentially offers the ability to perform a safe, effective and faster cavotricuspid isthmus (CTI) ablation. Aims: We evaluated feasibility and efficacy of a vHP-SD (90 W/4 sec) temperature-controlled radiofrequency (RF) CTI ablation for AFL using a novel contact force (CF) sensing ablation catheter with micro-electrodes. Methods: Fifteen consecutive patients (median age 75 years (interquartile range, IQR: 67, 79), 67 % male) with documented typical AFL were prospectively enrolled and underwent vHP-SD based CTI ablation (90 W/4 sec). Durability of CTI block was proven by pacing maneuvers from both sides of the ablation line. Results: Complete CTI block using vHP-SD ablation was achieved in all patients (Figure 1). At median 23 (IQR 20; 39) RF applications over a median RF ablation time of 92 (IQR 78, 154) seconds were applied. It was not necessary to switch to the standard temperature-controlled mode to achieve durable CTI block. No periprocedural complications, no charring and no steam pops were observed. Conclusions: Very high-power short-duration (90 W/4 sec) CTI ablation for the treatment of typical AFL is feasible and efficient. Effective CTIAbstract: Funding Acknowledgements: Type of funding sources: None. Background: Catheter ablation for typical right atrial flutter (AFL) provides an effective treatment associated with encouraging clinical outcome. The novel micro-electrode ablation catheter allows very high-power short-duration (vHP-SD, 90 W/4 sec) ablation and potentially offers the ability to perform a safe, effective and faster cavotricuspid isthmus (CTI) ablation. Aims: We evaluated feasibility and efficacy of a vHP-SD (90 W/4 sec) temperature-controlled radiofrequency (RF) CTI ablation for AFL using a novel contact force (CF) sensing ablation catheter with micro-electrodes. Methods: Fifteen consecutive patients (median age 75 years (interquartile range, IQR: 67, 79), 67 % male) with documented typical AFL were prospectively enrolled and underwent vHP-SD based CTI ablation (90 W/4 sec). Durability of CTI block was proven by pacing maneuvers from both sides of the ablation line. Results: Complete CTI block using vHP-SD ablation was achieved in all patients (Figure 1). At median 23 (IQR 20; 39) RF applications over a median RF ablation time of 92 (IQR 78, 154) seconds were applied. It was not necessary to switch to the standard temperature-controlled mode to achieve durable CTI block. No periprocedural complications, no charring and no steam pops were observed. Conclusions: Very high-power short-duration (90 W/4 sec) CTI ablation for the treatment of typical AFL is feasible and efficient. Effective CTI block can be achieved in about 1.5 minutes of RF time. … (more)
- Is Part Of:
- Europace. Volume 24:Supplement 1(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Supplement 1(2022)
- Issue Display:
- Volume 24, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2022-0024-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-19
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac053.072 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml