Assessing alternatives to HEPA air purification requirements to reduce viral pathogen transmission in healthcare HVAC systems. (July 2022)
- Record Type:
- Journal Article
- Title:
- Assessing alternatives to HEPA air purification requirements to reduce viral pathogen transmission in healthcare HVAC systems. (July 2022)
- Main Title:
- Assessing alternatives to HEPA air purification requirements to reduce viral pathogen transmission in healthcare HVAC systems
- Authors:
- Bischoff, Werner
Ornelles, David
Ivey, Lauren
Payne, Bill - Abstract:
- Abstract : Background: High-efficiency particulate air (HEPA) filters are currently recommended when using recirculated air to eliminate the risk of pathogen transmission such as SARS-CoV-2 from one patient care area to the next. We tested the efficacy of lower-grade air filters in eliminating airborne virus transmission. Methods: We conducted an experiment in 2 adjacent exam rooms in an unoccupied hospital emergency unit. The HVAC system contained a 15, 000-cubic-feet-per-minute rooftop air handler. All outside air and exhaust dampers were closed during the trial (full air recirculation). We conducted experiments in 3 tests arms with varying grades of MERV filters (AAF Flanders, Louisville, KY): (1) control without filters, (2) MERV8+14 filters, and (3) MERV8+16 filters. We repeated 20-minute virus challenge runs 3 times per test arm. Live attenuated influenza vaccine (2 mL LAIV, FluMist Quadrivalent 2020/21, AstraZeneca, Wilmington, DE), was aerosolized into the HVAC system via a commercial nebulizer. Air was sampled using 3 six-stage Andersen air samplers placed in the center of the adjacent room. Environmental particle counts were collected using a particle counter (PEC-PCO-1, PCE Americas). Results: Concentrations of viral RNA were determined by qPCR, and viral concentrations (vg/mL) in each stage of each arm were compared directly. Pairwise comparisons of the virus and particle burdens across each stage of each test arm were made using a general linear model. LAIV wasAbstract : Background: High-efficiency particulate air (HEPA) filters are currently recommended when using recirculated air to eliminate the risk of pathogen transmission such as SARS-CoV-2 from one patient care area to the next. We tested the efficacy of lower-grade air filters in eliminating airborne virus transmission. Methods: We conducted an experiment in 2 adjacent exam rooms in an unoccupied hospital emergency unit. The HVAC system contained a 15, 000-cubic-feet-per-minute rooftop air handler. All outside air and exhaust dampers were closed during the trial (full air recirculation). We conducted experiments in 3 tests arms with varying grades of MERV filters (AAF Flanders, Louisville, KY): (1) control without filters, (2) MERV8+14 filters, and (3) MERV8+16 filters. We repeated 20-minute virus challenge runs 3 times per test arm. Live attenuated influenza vaccine (2 mL LAIV, FluMist Quadrivalent 2020/21, AstraZeneca, Wilmington, DE), was aerosolized into the HVAC system via a commercial nebulizer. Air was sampled using 3 six-stage Andersen air samplers placed in the center of the adjacent room. Environmental particle counts were collected using a particle counter (PEC-PCO-1, PCE Americas). Results: Concentrations of viral RNA were determined by qPCR, and viral concentrations (vg/mL) in each stage of each arm were compared directly. Pairwise comparisons of the virus and particle burdens across each stage of each test arm were made using a general linear model. LAIV was detected in the control arm at a virus burden of 2, 277 vg/mL, indicating a >6.5 log reduction of the virus released in the HVAC system (8.8×109 total vg). In the second arm, the MERV8+MERV14 filters demonstrated in a 13-fold decrease in viral burden compared to the control arm (mean virus burden: 169 vg/mL, p Our study demonstrates that viral containing particles can be transported via a hospital HVAC system from one patient room to the next. Considering the decrease in detectable virus within the HVAC system, the combination of MERV8+MERV16 filters reduced the virus burden reaching an adjacent room to levels well below the human infectious dosages for influenza and other highly infective viruses. Conclusions: Our findings indicate that MERV8+MERV16 filters provide protection against virus transmission through HVAC systems and are a cost-conscious alternative to HEPA filters. Funding: None Disclosures: None … (more)
- Is Part Of:
- Antimicrobial stewardship & healthcare epidemiology. Volume 2(2022)Supplement 1
- Journal:
- Antimicrobial stewardship & healthcare epidemiology
- Issue:
- Volume 2(2022)Supplement 1
- Issue Display:
- Volume 2, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 2
- Issue:
- 1
- Issue Sort Value:
- 2022-0002-0001-0000
- Page Start:
- s85
- Page End:
- s85
- Publication Date:
- 2022-07
- Subjects:
- Anti-infective agents -- Periodicals
Nosocomial infections -- Prevention -- Periodicals
Epidemiology -- Periodicals
614.44 - Journal URLs:
- https://www.cambridge.org/core/journals/antimicrobial-stewardship-and-healthcare-epidemiology/latest-issue ↗
- DOI:
- 10.1017/ash.2022.217 ↗
- Languages:
- English
- ISSNs:
- 2732-494X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 22019.xml