0720 Accuracy of WatchPat Portable Sleep Monitoring and Sleep Assessment in Patients with Atrial Fibrillation. (25th May 2022)
- Record Type:
- Journal Article
- Title:
- 0720 Accuracy of WatchPat Portable Sleep Monitoring and Sleep Assessment in Patients with Atrial Fibrillation. (25th May 2022)
- Main Title:
- 0720 Accuracy of WatchPat Portable Sleep Monitoring and Sleep Assessment in Patients with Atrial Fibrillation
- Authors:
- Roth, Robert
Stafford, Patrick
Mehta, Nishaki
Bilchick, Kenneth
Davis, Eric
Bonner, Heather
Sobremonte-King, Michelle
Cho, Yelim
Kwon, Younghoon - Abstract:
- Abstract: Introduction: Obstructive sleep apnea(OSA) is an established risk factor for atrial fibrillation(AF), necessitating early diagnosis and management. Home-based sleep-monitoring technology has become a mainstream diagnostic modality. Peripheral arterial tonometry (PAT) device is increasingly being used to screen for OSA in patients with AF. Our study aimed to examine the accuracy of Watch-PAT (WP) in OSA evaluation, and night-to-night variability of sleep characteristics as measured by WP when used during consecutive night sleep studies. Methods: Patients with history of AF undergoing clinically indicated PSG were prospectively enrolled and had concurrent WP while undergoing PSG. Patients then were studied again using WP over two consecutive days at home. We compared agreement of OSA severity(defined as no OSA[AHI (apnea hypopnea index)<5], mild OSA[15>AHI³5], moderate OSA[30>AHI³15], severe OSA[AHI>30]) and total sleep time(TST) using Cohen's Kappa(K) for categorical and Bland-Altman plots for continuous variables. To further characterize PSG versus WP, the cohort was stratified into paroxysmal versus persistent AF types. 1A/1B hypopnea scoring criteria was defined as per AASM. Results: Our cohort included 24 patients with AF(80% male, mean age 68y). Most patients had clinically defined OSA(AHI³5). Patients with persistent AF had more severe OSA than those with paroxysmal AF (severe OSA present in 60% vs. 29%). Comparison of PSG to concurrently conducted WP in theAbstract: Introduction: Obstructive sleep apnea(OSA) is an established risk factor for atrial fibrillation(AF), necessitating early diagnosis and management. Home-based sleep-monitoring technology has become a mainstream diagnostic modality. Peripheral arterial tonometry (PAT) device is increasingly being used to screen for OSA in patients with AF. Our study aimed to examine the accuracy of Watch-PAT (WP) in OSA evaluation, and night-to-night variability of sleep characteristics as measured by WP when used during consecutive night sleep studies. Methods: Patients with history of AF undergoing clinically indicated PSG were prospectively enrolled and had concurrent WP while undergoing PSG. Patients then were studied again using WP over two consecutive days at home. We compared agreement of OSA severity(defined as no OSA[AHI (apnea hypopnea index)<5], mild OSA[15>AHI³5], moderate OSA[30>AHI³15], severe OSA[AHI>30]) and total sleep time(TST) using Cohen's Kappa(K) for categorical and Bland-Altman plots for continuous variables. To further characterize PSG versus WP, the cohort was stratified into paroxysmal versus persistent AF types. 1A/1B hypopnea scoring criteria was defined as per AASM. Results: Our cohort included 24 patients with AF(80% male, mean age 68y). Most patients had clinically defined OSA(AHI³5). Patients with persistent AF had more severe OSA than those with paroxysmal AF (severe OSA present in 60% vs. 29%). Comparison of PSG to concurrently conducted WP in the lab showed substantial agreement in OSA severity by both 1A(K=0.623) and 1B(0.706) criteria. Percent difference in TST between PSG versus WP in the paroxysmal AF versus persistent groups was not statistically significant(p=0.387). Comparing two consecutive at-home WP tests showed substantial agreement in OSA severity measures(1A=0.872, 1B=0.889). Bland-Altman plots for TST and sleep architecture showed ³95% of residuals within 2 standard-deviations, suggesting intertester agreement. Confidence intervals were broad in these plots reflecting our small sample size. Conclusion: Our findings demonstrate that WP is a reasonable alternative to PSG, particularly if using the 1B criteria to diagnose OSA. Additionally, our results show that persistent versus paroxysmal AF does not seem to affect the results of WP tests. Night to night variability of OSA measures and TST was small. Future studies should verify the results of our study in a larger cohort. Support (If Any): … (more)
- Is Part Of:
- Sleep. Volume 45(2022)Supplement 1
- Journal:
- Sleep
- Issue:
- Volume 45(2022)Supplement 1
- Issue Display:
- Volume 45, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 45
- Issue:
- 1
- Issue Sort Value:
- 2022-0045-0001-0000
- Page Start:
- A315
- Page End:
- A315
- Publication Date:
- 2022-05-25
- Subjects:
- Sleep -- Physiological aspects -- Periodicals
Sleep disorders -- Periodicals
Sommeil -- Aspect physiologique -- Périodiques
Sommeil, Troubles du -- Périodiques
Sleep disorders
Sleep -- Physiological aspects
Sleep -- physiological aspects
Sleep Wake Disorders
Psychophysiology
Electronic journals
Periodicals
616.8498 - Journal URLs:
- http://bibpurl.oclc.org/web/21399 ↗
http://www.journalsleep.org/ ↗
https://academic.oup.com/sleep ↗
http://www.oxfordjournals.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=369&action=archive ↗ - DOI:
- 10.1093/sleep/zsac079.716 ↗
- Languages:
- English
- ISSNs:
- 0161-8105
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22016.xml