C32 TRANSCATHETER LEAK OCCLUSION WITH ENDOVASCULAR COILS FOLLOWING LEFT ATRIAL APPENDAGE CLOSURE: PROCEDURAL SUCCESS AND OUTCOMES BEFORE AND AFTER LEAK CLOSURE. (18th May 2022)
- Record Type:
- Journal Article
- Title:
- C32 TRANSCATHETER LEAK OCCLUSION WITH ENDOVASCULAR COILS FOLLOWING LEFT ATRIAL APPENDAGE CLOSURE: PROCEDURAL SUCCESS AND OUTCOMES BEFORE AND AFTER LEAK CLOSURE. (18th May 2022)
- Main Title:
- C32 TRANSCATHETER LEAK OCCLUSION WITH ENDOVASCULAR COILS FOLLOWING LEFT ATRIAL APPENDAGE CLOSURE: PROCEDURAL SUCCESS AND OUTCOMES BEFORE AND AFTER LEAK CLOSURE
- Authors:
- Magnocavallo, M
Della Rocca, D
Lavalle, C
Mohanty, S
Carola, G
Bassiouny, M
Al–Ahmad, A
Burkhardt, D
Gallinghouse, J
Lakireddy, D
Horton, R
Di Biase, L
Natale, A - Abstract:
- Abstract: Background: Whether residual peri–device leaks after left atrial appendage occlusion (LAAO) portend a higher risk of thromboembolism (TE), it is still a matter of debate. Objectives: We report the TE risk in patients with incomplete LAA closure before and after leak closure with endovascular coils. Methods: One hundred twenty–four Watchman patients with a significant (≥3mm) leak (mean age: 74 ± 9 years; 66.9% males; CHA2DS2–VASc: 4.4 ± 1.7; HAS–BLED: 3.1 ± 1) underwent LAA leak coiling. The expected annual TE risk was estimated based on the patients' CHA2DS2–VASc and compared with the annualized incidence observed before and after coiling (Fig.1B ). Results: The time between LAAO and leak coiling was 8±6 months [83 patients–year (PY)]; before leak closure, 6 (4.8%) patients had a TE event (annualized rate: 7.2%). Coil deployment was successful in all cases [median n. of coils deployed: 5 (IQR: 2–10)]. Procedure time was 79 ± 40 min; the mean volume of iodinated contrast medium used was 80 ± 43mL. The overall complication rate was 2.4% (1 pericardial tamponade, 2 pericardial effusion). Follow–up TEE after 61±14 days revealed complete LAA sealing or a negligible leak in 117 cases (94.4%); the remaining 7 patients had a moderate leak. During 14±6 months post–coiling (145 PY), 1 (0.8%) patient suffered from stroke. The incidence of TE events was significantly lower after leak closure than before coiling (0.8% vs 4.8%; log–rank p = 0.02; Fig.1A ). The annualized TEAbstract: Background: Whether residual peri–device leaks after left atrial appendage occlusion (LAAO) portend a higher risk of thromboembolism (TE), it is still a matter of debate. Objectives: We report the TE risk in patients with incomplete LAA closure before and after leak closure with endovascular coils. Methods: One hundred twenty–four Watchman patients with a significant (≥3mm) leak (mean age: 74 ± 9 years; 66.9% males; CHA2DS2–VASc: 4.4 ± 1.7; HAS–BLED: 3.1 ± 1) underwent LAA leak coiling. The expected annual TE risk was estimated based on the patients' CHA2DS2–VASc and compared with the annualized incidence observed before and after coiling (Fig.1B ). Results: The time between LAAO and leak coiling was 8±6 months [83 patients–year (PY)]; before leak closure, 6 (4.8%) patients had a TE event (annualized rate: 7.2%). Coil deployment was successful in all cases [median n. of coils deployed: 5 (IQR: 2–10)]. Procedure time was 79 ± 40 min; the mean volume of iodinated contrast medium used was 80 ± 43mL. The overall complication rate was 2.4% (1 pericardial tamponade, 2 pericardial effusion). Follow–up TEE after 61±14 days revealed complete LAA sealing or a negligible leak in 117 cases (94.4%); the remaining 7 patients had a moderate leak. During 14±6 months post–coiling (145 PY), 1 (0.8%) patient suffered from stroke. The incidence of TE events was significantly lower after leak closure than before coiling (0.8% vs 4.8%; log–rank p = 0.02; Fig.1A ). The annualized TE rates were 7.2% before and 0.7% after leak closure (Fig. 1A ). According to the expected rate estimated from the patients' CHA2DS2–VASc (9.8%), LAAO with and without significant leaks yielded to a risk reduction of 26.5% and 92.9% (Fig. 1B ). Conclusions: Transcatheter leak occlusion via endovascular coils was safe. LAA closure led to a significant reduction in TE events. … (more)
- Is Part Of:
- European heart journal supplements. Volume 24(2022)Supplement C
- Journal:
- European heart journal supplements
- Issue:
- Volume 24(2022)Supplement C
- Issue Display:
- Volume 24, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 3
- Issue Sort Value:
- 2022-0024-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-18
- Subjects:
- Cardiology -- Periodicals
Cardiology -- Europe -- Periodicals
616.12005 - Journal URLs:
- http://eurheartjsupp.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/suac011.031 ↗
- Languages:
- English
- ISSNs:
- 1520-765X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717510
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22013.xml