P-20 Galilei topography vs Anterion topography. Same patient, different results?. (26th May 2022)
- Record Type:
- Journal Article
- Title:
- P-20 Galilei topography vs Anterion topography. Same patient, different results?. (26th May 2022)
- Main Title:
- P-20 Galilei topography vs Anterion topography. Same patient, different results?
- Authors:
- Yusuf, Mustafa
Bong, Chung
Dharni, Akash - Abstract:
- Abstract : *Correspondence - Mustafa Yusuf: mustafayusuf@nhs.net Objective: Corneal topography is a crucial part of the decision making process in clinics throughout the country. numerous machines are available, therefore it is important if a patient has topography performed on one device it produces consistent results on another device. Our service is somewhat unique with eye clinics running on two different sites with two different topography machines. This study aims to compare the commonly used Galilei machine with the newer Anterion machine to see if the measurements are comparable. Methods and Analysis: We identified 20 patients (between the ages of 15 and 40) with a diagnosis of keratoconus who had undergone both Galilei and Anterion topography. Only those patients who had undergone both scans within a 2-week time frame (and should therefore have very similar topography readings) were included. We compared Flat Sim K, Steep Sim K, K Max and Pachymetry readings between the two devices. Results: The mean difference in Flat Sim K was 0.41. The largest difference was 1.1. The mean difference in Steep Sim K was 0.52. The largest difference 1.8. The mean difference in K Max was 0.73. The largest difference 2.1. The mean difference in pachymetry was 11 µm. The largest difference 21 µm. Conclusion: There was considerable differences in measurements between the two devices, with K Max and Pachymetry showing the most disparity. We therefore recommend caution when deciding upon,Abstract : *Correspondence - Mustafa Yusuf: mustafayusuf@nhs.net Objective: Corneal topography is a crucial part of the decision making process in clinics throughout the country. numerous machines are available, therefore it is important if a patient has topography performed on one device it produces consistent results on another device. Our service is somewhat unique with eye clinics running on two different sites with two different topography machines. This study aims to compare the commonly used Galilei machine with the newer Anterion machine to see if the measurements are comparable. Methods and Analysis: We identified 20 patients (between the ages of 15 and 40) with a diagnosis of keratoconus who had undergone both Galilei and Anterion topography. Only those patients who had undergone both scans within a 2-week time frame (and should therefore have very similar topography readings) were included. We compared Flat Sim K, Steep Sim K, K Max and Pachymetry readings between the two devices. Results: The mean difference in Flat Sim K was 0.41. The largest difference was 1.1. The mean difference in Steep Sim K was 0.52. The largest difference 1.8. The mean difference in K Max was 0.73. The largest difference 2.1. The mean difference in pachymetry was 11 µm. The largest difference 21 µm. Conclusion: There was considerable differences in measurements between the two devices, with K Max and Pachymetry showing the most disparity. We therefore recommend caution when deciding upon, for example keratoconus progression, in a patient who has undergone topography on two different devices. … (more)
- Is Part Of:
- BMJ open ophthalmology. Volume 7(2022)Supplement 1
- Journal:
- BMJ open ophthalmology
- Issue:
- Volume 7(2022)Supplement 1
- Issue Display:
- Volume 7, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2022-0007-0001-0000
- Page Start:
- A6
- Page End:
- A6
- Publication Date:
- 2022-05-26
- Subjects:
- Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjophth.bmj.com/ ↗ - DOI:
- 10.1136/bmjophth-2022-BCM.17 ↗
- Languages:
- English
- ISSNs:
- 2397-3269
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22006.xml