Impact on dose distribution and volume changes of a bioabsorbable polyglycolic acid spacer during chemo-proton therapy for a pediatric Ewing sarcoma. (22nd September 2020)
- Record Type:
- Journal Article
- Title:
- Impact on dose distribution and volume changes of a bioabsorbable polyglycolic acid spacer during chemo-proton therapy for a pediatric Ewing sarcoma. (22nd September 2020)
- Main Title:
- Impact on dose distribution and volume changes of a bioabsorbable polyglycolic acid spacer during chemo-proton therapy for a pediatric Ewing sarcoma
- Authors:
- Kimura, Mitsuhiro
Asai, Kumiko
Iwata, Hiromitsu
Ogino, Hiroyuki
Ito, Yasuhiko
Kamei, Michi
Takagi, Daisuke
Maeda, Naoko
Shibamoto, Yuta - Abstract:
- ABSTRACT: The clinical utility of a recently developed bioabsorbable polyglycolic acid (PGA) spacer has not yet been established in pediatric patients; therefore, we aimed to investigate its utility during chemo-proton therapy for pediatric cancer. Proton depth–dose curves were obtained in a water phantom with or without the spacer. Computed tomography (CT) scans were performed for the PGA spacer immersed in saline for 2 weeks to measure CT numbers and estimate the relative stopping power (RSP) for the proton beams. The spacer was placed in a patient with sacral Ewing sarcoma receiving 55.8 Gy [relative biological effectiveness (RBE)] in 31 fractions and was evaluated using CT scans performed every other week. In addition, the images were used to quantitatively evaluate changes in volume and RSP of the spacer and dose distributions in normal tissues. The spacer immersed in saline had a CT number of 91 ± 7 (mean ± standard deviation) Hounsfield units, and the corresponding RSP was predicted to be 1.07 ± 0.01. The measured RSP agreed with the predicted one. The volumes of the large bowel and rectum receiving ≥45 Gy(RBE) (V45Gy ) were significantly reduced by placing the spacer; V45Gy without and with the spacer were 48.5 and 0.01%, respectively, for the rectum and 7.2 and 0%, respectively, for the large bowel. The volume of the spacer and RSP decreased at rates of 4.6 and 0.44% per week, respectively, whereas the target dose coverage was maintained until the end of treatment.ABSTRACT: The clinical utility of a recently developed bioabsorbable polyglycolic acid (PGA) spacer has not yet been established in pediatric patients; therefore, we aimed to investigate its utility during chemo-proton therapy for pediatric cancer. Proton depth–dose curves were obtained in a water phantom with or without the spacer. Computed tomography (CT) scans were performed for the PGA spacer immersed in saline for 2 weeks to measure CT numbers and estimate the relative stopping power (RSP) for the proton beams. The spacer was placed in a patient with sacral Ewing sarcoma receiving 55.8 Gy [relative biological effectiveness (RBE)] in 31 fractions and was evaluated using CT scans performed every other week. In addition, the images were used to quantitatively evaluate changes in volume and RSP of the spacer and dose distributions in normal tissues. The spacer immersed in saline had a CT number of 91 ± 7 (mean ± standard deviation) Hounsfield units, and the corresponding RSP was predicted to be 1.07 ± 0.01. The measured RSP agreed with the predicted one. The volumes of the large bowel and rectum receiving ≥45 Gy(RBE) (V45Gy ) were significantly reduced by placing the spacer; V45Gy without and with the spacer were 48.5 and 0.01%, respectively, for the rectum and 7.2 and 0%, respectively, for the large bowel. The volume of the spacer and RSP decreased at rates of 4.6 and 0.44% per week, respectively, whereas the target dose coverage was maintained until the end of treatment. The PGA spacer was considered effective for pediatric cancer patients undergoing chemo-proton therapy. … (more)
- Is Part Of:
- Journal of radiation research. Volume 61:Number 6(2020:Nov.)
- Journal:
- Journal of radiation research
- Issue:
- Volume 61:Number 6(2020:Nov.)
- Issue Display:
- Volume 61, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 61
- Issue:
- 6
- Issue Sort Value:
- 2020-0061-0006-0000
- Page Start:
- 952
- Page End:
- 958
- Publication Date:
- 2020-09-22
- Subjects:
- polyglycolic acid (PGA) spacer -- pediatric cancer -- chemo-proton therapy -- volume changes
Radiology, Medical -- Periodicals
Radiobiology -- Periodicals
Radiation -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/15847 ↗
http://bibpurl.oclc.org/web/7828 ↗
http://www.journalarchive.jst.go.jp/english/jnltop_en.php?cdjournal=jrr1960 ↗
https://www.jstage.jst.go.jp/browse/jrr ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/jrr/rraa087 ↗
- Languages:
- English
- ISSNs:
- 0449-3060
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21984.xml