Benchmarking Geant4 hadronic models for prompt‐γ monitoring in carbon ion therapy. Issue 8 (30th June 2017)
- Record Type:
- Journal Article
- Title:
- Benchmarking Geant4 hadronic models for prompt‐γ monitoring in carbon ion therapy. Issue 8 (30th June 2017)
- Main Title:
- Benchmarking Geant4 hadronic models for prompt‐γ monitoring in carbon ion therapy
- Authors:
- Vanstalle, Marie
Mattei, Ilaria
Sarti, Alessio
Bellini, Fabio
Bini, Fabiano
Collamati, Francesco
Lucia, Erika De
Durante, Marco
Faccini, Riccardo
Ferroni, Fernando
Finck, Christian
Fiore, Salvatore
Marafini, Michela
Patera, Vincenzo
Piersanti, Luca
Rovituso, Marta
Schuy, Christoph
Sciubba, Adalberto
Traini, Giacomo
Voena, Cecilia
Tessa, Chiara La - Abstract:
- Abstract : Purpose: The real‐time monitoring of the spread‐out Bragg peak would allow the planned dose delivered during treatment to be directly verified, but this poses a major challenge in modern ion beam therapy. A possible method to achieve this goal is to exploit the production of secondary particles by the nuclear reactions of the beam with the patient and correlate their emission profile to the planned target volume position. In this study, we present both the production rate and energy spectra of the prompt‐ γ produced by the interactions of the 12 C ion beam with a polymethyl methacrylate (PMMA) target. We also assess three different Monte Carlo models for prompt‐ γ simulation based on our experimental data. Methods: The experiment was carried out at the GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany with a 220 MeV/u 12 C ions beam impinging on a 5× 5× 20 cm 3 polymethyl methacrylate beam stopping target, with the prompt‐ γ being detected by a hexagonally‐shaped barium fluoride scintillator with a circumscribed radius of 5.4 cm and a length of 14 cm, placed at 60° and 90° with respect to the beam direction. Monte Carlo simulations were carried out with three different hadronic models from the Geant4 code: binary ion cascade (BIC), quantum molecular dynamics (QMD), and Liege intranuclear cascade (INCL ++ ). Results: An experimental prompt‐ γ yield of 1.06 × 10 −2 sr −1 was measured at 90°. A good agreement was observed between the shapes of theAbstract : Purpose: The real‐time monitoring of the spread‐out Bragg peak would allow the planned dose delivered during treatment to be directly verified, but this poses a major challenge in modern ion beam therapy. A possible method to achieve this goal is to exploit the production of secondary particles by the nuclear reactions of the beam with the patient and correlate their emission profile to the planned target volume position. In this study, we present both the production rate and energy spectra of the prompt‐ γ produced by the interactions of the 12 C ion beam with a polymethyl methacrylate (PMMA) target. We also assess three different Monte Carlo models for prompt‐ γ simulation based on our experimental data. Methods: The experiment was carried out at the GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany with a 220 MeV/u 12 C ions beam impinging on a 5× 5× 20 cm 3 polymethyl methacrylate beam stopping target, with the prompt‐ γ being detected by a hexagonally‐shaped barium fluoride scintillator with a circumscribed radius of 5.4 cm and a length of 14 cm, placed at 60° and 90° with respect to the beam direction. Monte Carlo simulations were carried out with three different hadronic models from the Geant4 code: binary ion cascade (BIC), quantum molecular dynamics (QMD), and Liege intranuclear cascade (INCL ++ ). Results: An experimental prompt‐ γ yield of 1.06 × 10 −2 sr −1 was measured at 90°. A good agreement was observed between the shapes of the experimental and simulated energy spectra, especially with the INCL ++ physics list. The prompt‐ γ yield obtained with this physics list was compatible with the measurement within 2 σ, with a relative difference of 26% on average. BIC and QMD physics lists proved to be less accurate than INCL ++, with the difference between the measured and simulated yields exceeding 100%. The differences between the three physics lists were ascribed to important discrepancies between the models of the physical processes producing prompt‐ γ emissions. Conclusion: In conclusion, this study provides prompt‐ γ yield values in agreement with previously published results for different carbon ions energies. This work demonstrates that the INCL ++ physics list from Geant4 is more accurate than BIC and QMD to reproduce prompt‐ γ emission properties. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 8(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 8(2017)
- Issue Display:
- Volume 44, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 8
- Issue Sort Value:
- 2017-0044-0008-0000
- Page Start:
- 4276
- Page End:
- 4286
- Publication Date:
- 2017-06-30
- Subjects:
- carbon ion -- Geant4 -- hadronic models -- hadrontherapy -- prompt‐γ
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12348 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21971.xml