Surgery versus Imaging in Non‐Localizing Primary Hyperparathyroidism: A Cost‐Effectiveness Model. (17th February 2020)
- Record Type:
- Journal Article
- Title:
- Surgery versus Imaging in Non‐Localizing Primary Hyperparathyroidism: A Cost‐Effectiveness Model. (17th February 2020)
- Main Title:
- Surgery versus Imaging in Non‐Localizing Primary Hyperparathyroidism: A Cost‐Effectiveness Model
- Authors:
- Frank, Ethan
Watson, WayAnne
Fujimoto, Shannon
De Andrade Filho, Pedro
Inman, Jared
Simental, Alfred - Abstract:
- Abstract : Objective: To determine whether advanced imaging is cost‐effective compared to primary bilateral neck exploration in the management of non‐localizing primary hyperparathyroidism. Study Design: Cost‐effectiveness analysis. Methods: Cost‐effectiveness analysis based on decision tree model and available Medicare financial data using data from 347 consecutive patients having parathyroidectomy for primary hyperparathyroidism with either 1) positive, concordant ultrasound and sestamibi or 2) negative sestamibi and negative ultrasound. Results: Bilateral neck exploration (BNE) costs $9578 and has a success rate of 97.3%. Single photon emission computed tomography (SPECT) + minimally invasive parathyroidectomy (MIP) was modeled to have a total cost of $8197 with a success rate of 98.6%. SPECT/computed tomography (CT) + MIP was modeled to have a total cost of $8271 and a 98.9% success rate. Four‐dimensional (4D)–CT + MIP was modeled to cost $8146 with a success rate of 99%. Incremental cost‐effectiveness ratios (IECR) (as compared to BNE) were −536.1, −605.5, and −701.6 ($/percent cure rate) for SPECT, SPECT/CT, and 4D‐CT respectively. One‐way sensitivity analyses demonstrate the change in IECR and cut‐off points (IECR = 0) for four major variables. Conclusions: In patients with non‐localizing primary hyperparathyroidism, advanced imaging is associated with cost‐savings compared to routine bilateral neck exploration. Increased cost‐savings were predicted with increasedAbstract : Objective: To determine whether advanced imaging is cost‐effective compared to primary bilateral neck exploration in the management of non‐localizing primary hyperparathyroidism. Study Design: Cost‐effectiveness analysis. Methods: Cost‐effectiveness analysis based on decision tree model and available Medicare financial data using data from 347 consecutive patients having parathyroidectomy for primary hyperparathyroidism with either 1) positive, concordant ultrasound and sestamibi or 2) negative sestamibi and negative ultrasound. Results: Bilateral neck exploration (BNE) costs $9578 and has a success rate of 97.3%. Single photon emission computed tomography (SPECT) + minimally invasive parathyroidectomy (MIP) was modeled to have a total cost of $8197 with a success rate of 98.6%. SPECT/computed tomography (CT) + MIP was modeled to have a total cost of $8271 and a 98.9% success rate. Four‐dimensional (4D)–CT + MIP was modeled to cost $8146 with a success rate of 99%. Incremental cost‐effectiveness ratios (IECR) (as compared to BNE) were −536.1, −605.5, and −701.6 ($/percent cure rate) for SPECT, SPECT/CT, and 4D‐CT respectively. One‐way sensitivity analyses demonstrate the change in IECR and cut‐off points (IECR = 0) for four major variables. Conclusions: In patients with non‐localizing primary hyperparathyroidism, advanced imaging is associated with cost‐savings compared to routine bilateral neck exploration. Increased cost‐savings were predicted with increased imaging accuracy and decreased imaging costs. Increasing time for BNE or decreasing time for MIP were associated with increased cost savings. Level of Evidence: III Laryngoscope, 2020 … (more)
- Is Part Of:
- Laryngoscope. Volume 130:Number 12(2020)
- Journal:
- Laryngoscope
- Issue:
- Volume 130:Number 12(2020)
- Issue Display:
- Volume 130, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 12
- Issue Sort Value:
- 2020-0130-0012-0000
- Page Start:
- E963
- Page End:
- E969
- Publication Date:
- 2020-02-17
- Subjects:
- Hyperparathyroidism -- cost‐effectiveness -- bilateral neck exploration -- non‐localizing -- minimally invasive parathyroidectomy
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.28566 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21975.xml