An evaluation of the pharmacokinetics of tiotropium following a single-dose inhalation in healthy subjects using an ultra-sensitive bioanalytical method. (2nd December 2019)
- Record Type:
- Journal Article
- Title:
- An evaluation of the pharmacokinetics of tiotropium following a single-dose inhalation in healthy subjects using an ultra-sensitive bioanalytical method. (2nd December 2019)
- Main Title:
- An evaluation of the pharmacokinetics of tiotropium following a single-dose inhalation in healthy subjects using an ultra-sensitive bioanalytical method
- Authors:
- Bouhajib, Mohammed
Tayab, Zia - Abstract:
- Abstract: Objective and significance: The systemic bioavailability of tiotropium following administration via inhalation is known to be very low. A validated ultra-sensitive bioanalytical method with the lowest lower limit of quantitation (LLOQ) was developed and used to evaluate the complete pharmacokinetic profile of tiotropium. Methods: This was a pharmacokinetic study performed in 18 healthy subjects. Each subject was administered a dose of 18 mcg of tiotropium from a dry powder inhaler (DPI). The subjects' plasma tiotropium concentrations were assayed with LLOQ of 0.1 pg/mL. Results: The results showed a mean C max of 4.98 ± 3.55 pg/mL, and a median ( t max ) of 3.6 minutes (range: 1.8–12 minutes). The means for area under the concentration–time curve (AUC) from time zero hours to infinity (AUCinf ) and AUC from time zero hours to the time of the last measurable tiotropium concentration (AUC t ) were 51.11 ± 27.4 pg*h/mL and 37.37 ± 23.38 pg*h/mL, respectively. The mean apparent elimination half-life ( t 1/2 ) was 68.02 ± 24.55 hours. This calculated half-life is longer than what others have reported where a less sensitive LLOQ was used. Conclusion: The lower LLOQ enabled further insight into the pharmacokinetics of tiotropium that was not possible with other analytical methods. With this method, we were able to quantify tiotropium concentrations as early as one minute following drug administration and up to 144 hours after dosing. The application of this method willAbstract: Objective and significance: The systemic bioavailability of tiotropium following administration via inhalation is known to be very low. A validated ultra-sensitive bioanalytical method with the lowest lower limit of quantitation (LLOQ) was developed and used to evaluate the complete pharmacokinetic profile of tiotropium. Methods: This was a pharmacokinetic study performed in 18 healthy subjects. Each subject was administered a dose of 18 mcg of tiotropium from a dry powder inhaler (DPI). The subjects' plasma tiotropium concentrations were assayed with LLOQ of 0.1 pg/mL. Results: The results showed a mean C max of 4.98 ± 3.55 pg/mL, and a median ( t max ) of 3.6 minutes (range: 1.8–12 minutes). The means for area under the concentration–time curve (AUC) from time zero hours to infinity (AUCinf ) and AUC from time zero hours to the time of the last measurable tiotropium concentration (AUC t ) were 51.11 ± 27.4 pg*h/mL and 37.37 ± 23.38 pg*h/mL, respectively. The mean apparent elimination half-life ( t 1/2 ) was 68.02 ± 24.55 hours. This calculated half-life is longer than what others have reported where a less sensitive LLOQ was used. Conclusion: The lower LLOQ enabled further insight into the pharmacokinetics of tiotropium that was not possible with other analytical methods. With this method, we were able to quantify tiotropium concentrations as early as one minute following drug administration and up to 144 hours after dosing. The application of this method will allow for studies to be designed properly and enable further investigations into the pharmacokinetics of tiotropium. … (more)
- Is Part Of:
- Drug development and industrial pharmacy. Volume 45:Number 12(2019)
- Journal:
- Drug development and industrial pharmacy
- Issue:
- Volume 45:Number 12(2019)
- Issue Display:
- Volume 45, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 12
- Issue Sort Value:
- 2019-0045-0012-0000
- Page Start:
- 1915
- Page End:
- 1920
- Publication Date:
- 2019-12-02
- Subjects:
- Tiotropium -- pharmacokinetics -- lower limit of quantitation -- sensitivity -- inhalation
Pharmaceutical chemistry -- Periodicals
Pharmaceutical industry -- Periodicals
Drug Industry -- Periodicals
Technology, Pharmaceutical -- Periodicals
615.05 - Journal URLs:
- http://informahealthcare.com/loi/ddi ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/03639045.2019.1680993 ↗
- Languages:
- English
- ISSNs:
- 0363-9045
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.116000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21971.xml