ISB clinical biomechanics award winner 2021: Tibio-femoral kinematics of natural versus replaced knees – A comparison using dynamic videofluoroscopy. (June 2022)
- Record Type:
- Journal Article
- Title:
- ISB clinical biomechanics award winner 2021: Tibio-femoral kinematics of natural versus replaced knees – A comparison using dynamic videofluoroscopy. (June 2022)
- Main Title:
- ISB clinical biomechanics award winner 2021: Tibio-femoral kinematics of natural versus replaced knees – A comparison using dynamic videofluoroscopy
- Authors:
- Postolka, Barbara
Taylor, William R.
List, Renate
Fucentese, Sandro F.
Koch, Peter P.
Schütz, Pascal - Abstract:
- Abstract: Background: A comparison of natural versus replaced tibio-femoral kinematics in vivo during challenging activities of daily living can help provide a detailed understanding of the mechanisms leading to unsatisfactory results and lay the foundations for personalised implant selection and surgical implantation, but also enhance further development of implant designs towards restoring physiological knee function. The aim of this study was to directly compare in vivo tibio-femoral kinematics in natural versus replaced knees throughout complete cycles of different gait activities using dynamic videofluoroscopy. Methods: Twenty-seven healthy and 30 total knee replacement subjects (GMK Sphere, GMK PS, GMK UC) were assessed during multiple complete gait cycles of level walking, downhill walking, and stair descent using dynamic videofluoroscopy. Following 2D/3D registration, tibio-femoral rotations, condylar antero-posterior translations, and the location of the centre of rotation were compared. Findings: The total knee replacement groups predominantly experienced reduced tibial internal/external rotation and altered medial and lateral condylar antero-posterior translations compared to natural knees. An average medial centre of rotation was found for the natural and GMK sphere groups in all three activities, whereas the GMK PS and UC groups experienced a more central to lateral centre of rotation. Interpretation: Each total knee replacement design exhibited characteristicAbstract: Background: A comparison of natural versus replaced tibio-femoral kinematics in vivo during challenging activities of daily living can help provide a detailed understanding of the mechanisms leading to unsatisfactory results and lay the foundations for personalised implant selection and surgical implantation, but also enhance further development of implant designs towards restoring physiological knee function. The aim of this study was to directly compare in vivo tibio-femoral kinematics in natural versus replaced knees throughout complete cycles of different gait activities using dynamic videofluoroscopy. Methods: Twenty-seven healthy and 30 total knee replacement subjects (GMK Sphere, GMK PS, GMK UC) were assessed during multiple complete gait cycles of level walking, downhill walking, and stair descent using dynamic videofluoroscopy. Following 2D/3D registration, tibio-femoral rotations, condylar antero-posterior translations, and the location of the centre of rotation were compared. Findings: The total knee replacement groups predominantly experienced reduced tibial internal/external rotation and altered medial and lateral condylar antero-posterior translations compared to natural knees. An average medial centre of rotation was found for the natural and GMK sphere groups in all three activities, whereas the GMK PS and UC groups experienced a more central to lateral centre of rotation. Interpretation: Each total knee replacement design exhibited characteristic motion patterns, with the GMK Sphere most closely replicating the medial centre of rotation found for natural knees. Despite substantial similarities between the subject groups, none of the implant geometries was able to replicate all aspects of natural tibio-femoral kinematics, indicating that different implant geometries might best address individual functional needs. Highlights: Each total knee replacement design exhibited characteristic motion patterns. GMK Sphere closest replicated the medial centre of rotation found in natural knees. No implant was able to replicate all aspects of natural tibio-femoral kinematics. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 96(2022)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 96(2022)
- Issue Display:
- Volume 96, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 96
- Issue:
- 2022
- Issue Sort Value:
- 2022-0096-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Tibio-femoral kinematics -- Videofluoroscopy -- Natural knee -- Total knee replacement -- Center of rotation
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2022.105667 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21960.xml