DIRECT COMPARISON OF INTERSECTING-TANGENTS VERSUS SECOND DERIVATIVE FOR DETERMINATION OF PULSE TRANSIT TIME AND PULSE WAVE VELOCITY. (June 2022)
- Record Type:
- Journal Article
- Title:
- DIRECT COMPARISON OF INTERSECTING-TANGENTS VERSUS SECOND DERIVATIVE FOR DETERMINATION OF PULSE TRANSIT TIME AND PULSE WAVE VELOCITY. (June 2022)
- Main Title:
- DIRECT COMPARISON OF INTERSECTING-TANGENTS VERSUS SECOND DERIVATIVE FOR DETERMINATION OF PULSE TRANSIT TIME AND PULSE WAVE VELOCITY
- Authors:
- Tairi, Amira
Obeid, Hasan
Fortier, Catherine
Paré, Mathilde
Côté, Nadège
Philibert, Emy
Garneau, Charles-Antoine
Duval, Karine
Groupil, Rémi
Agharazii, Mohsen - Abstract:
- Abstract : Objective: Arterial stiffness is a non-traditional risk factor for cardiovascular disease. Aortic stiffness is assessed by determination of pulse wave velocity using pulse transit time and the distance between carotid and femoral arteries. Transit time is obtained by using the foot-to-foot method to define the transit time through intersecting tangents algorithm or the point of maximal upstroke during systole (2nd derivative). Millasseau et al have proposed a formula for converting transit time between methods using SphygmoCor (intersecting tangents) and the Complior Analyse (2nd derivative). Based on a mathematical modeling of the proposed formula, there is discrepancy between values of pulse wave velocities, especially in subjects with higher aortic stiffness. The objective of this study is to directly compare the two methods using the same pressure waveforms obtained by the newer generation of Complior Analyse and using Millasseau's formula. Design and method: In a cross-sectional study of heterogeneous subjects, aortic stiffness was assessed by the Complior Analyse device which uses 2nd derivative. The pulse waveforms were extracted and used for the analysis by custom MATLAB algorithm for intersecting tangents, and the results were compared to the formula proposed by Millasseau. Results: The preliminary results of the first 24 patients (men: 71%; mean age: 61 ± 18 years) show that Millasseau's formula underestimates the transit times values by about 19% inAbstract : Objective: Arterial stiffness is a non-traditional risk factor for cardiovascular disease. Aortic stiffness is assessed by determination of pulse wave velocity using pulse transit time and the distance between carotid and femoral arteries. Transit time is obtained by using the foot-to-foot method to define the transit time through intersecting tangents algorithm or the point of maximal upstroke during systole (2nd derivative). Millasseau et al have proposed a formula for converting transit time between methods using SphygmoCor (intersecting tangents) and the Complior Analyse (2nd derivative). Based on a mathematical modeling of the proposed formula, there is discrepancy between values of pulse wave velocities, especially in subjects with higher aortic stiffness. The objective of this study is to directly compare the two methods using the same pressure waveforms obtained by the newer generation of Complior Analyse and using Millasseau's formula. Design and method: In a cross-sectional study of heterogeneous subjects, aortic stiffness was assessed by the Complior Analyse device which uses 2nd derivative. The pulse waveforms were extracted and used for the analysis by custom MATLAB algorithm for intersecting tangents, and the results were compared to the formula proposed by Millasseau. Results: The preliminary results of the first 24 patients (men: 71%; mean age: 61 ± 18 years) show that Millasseau's formula underestimates the transit times values by about 19% in comparison with the transit times obtained by the intersecting tangents method using MATLAB software (49, 8 ± 18, 8 ms vs 61, 6 ± 18, 6 ms; P < 0, 001). This results in an overestimation of the pulse wave velocities values by about 30% (13, 8 ± 3, 8 m/s vs 10, 6 ± 2, 7 m/s; P < 0, 001). Conclusions: Our preliminary results allow us to conclude that the values of pulse wave velocities obtained with Millasseau's formula are overestimated values when comparing with values obtained by using the intersecting tangents method. Increasing the number of subjects will allow us to examine the possibility of a more reliable formula for converting transit times from one method to the other. … (more)
- Is Part Of:
- Journal of hypertension. Volume 40(2022)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 40(2022)Supplement 1
- Issue Display:
- Volume 40, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 40
- Issue:
- 1
- Issue Sort Value:
- 2022-0040-0001-0000
- Page Start:
- e248
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000838028.06317.e4 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21969.xml