AMBULATORY BLOOD PRESSURE MONITORING: A NEW DIAGNOSTIC APPROACH FOR DETECTION OF HYPOTENSION IN REFLEX SYNCOPE (SYNABPM 1 STUDY). (June 2022)
- Record Type:
- Journal Article
- Title:
- AMBULATORY BLOOD PRESSURE MONITORING: A NEW DIAGNOSTIC APPROACH FOR DETECTION OF HYPOTENSION IN REFLEX SYNCOPE (SYNABPM 1 STUDY). (June 2022)
- Main Title:
- AMBULATORY BLOOD PRESSURE MONITORING: A NEW DIAGNOSTIC APPROACH FOR DETECTION OF HYPOTENSION IN REFLEX SYNCOPE (SYNABPM 1 STUDY)
- Authors:
- Rivasi, Giulia
Groppelli, Antonella
Brignole, Michele
Soranna, Davide
Zambon, Antonella
Bilo, Grzegorz
Pengo, Martino
Sharad, Bashaaer
Hamrefors, Viktor
Rafanelli, Martina
Testa, Giuseppe Dario
Rice, Ciara
Kenny, Rose Anne
Sutton, Richard
Ungar, Andrea
Fedorowski, Artur
Parati, Gianfranco - Abstract:
- Abstract : Objective: Diagnostic criteria for ambulatory blood pressure monitoring (ABPM) in patients with suspected reflex syncope are lacking. We hypothesized that patients with reflex syncope have a higher prevalence of systolic blood pressure (SBP) drops on ABPM. Design and method: We conducted a retrospective analysis comparing ABPM data from reflex syncope patients and controls, matched by average 24-hour SBP, age, sex and hypertension. Patients with constitutional hypotension, orthostatic hypotension, predominant cardioinhibition or competing causes of syncope were excluded. Daytime and night-time SBP drops (<110, 100, 90, 80 mmHg) were assessed. Hypotensive susceptibility was defined likely or possible for cut-offs achieving the highest sensitivity among those with specificity > 90% and 80–90%, respectively. Findings were validated in an independent sample. Results: In the Derivation cohort, daytime SBP drops were significantly more common in 158 syncope patients than 329 controls. One or more daytime drop < 90 mmHg provided the best diagnostic yield (91% specificity, 32% sensitivity, Odds Ratio [OR] = 4.6, p = 0.001). Two or more-daytime drops < 100 mmHg achieved 84% specificity and 40% sensitivity (OR = 3.5, p = 0.001). Results were confirmed in the Validation cohort: one or more daytime SBP drop < 90 mmHg provided 94% specificity and 29% sensitivity (OR = 6.2, p < 0.001), while two or more daytime SBP drops < 100 mmHg achieved 83% specificity and 35% sensitivityAbstract : Objective: Diagnostic criteria for ambulatory blood pressure monitoring (ABPM) in patients with suspected reflex syncope are lacking. We hypothesized that patients with reflex syncope have a higher prevalence of systolic blood pressure (SBP) drops on ABPM. Design and method: We conducted a retrospective analysis comparing ABPM data from reflex syncope patients and controls, matched by average 24-hour SBP, age, sex and hypertension. Patients with constitutional hypotension, orthostatic hypotension, predominant cardioinhibition or competing causes of syncope were excluded. Daytime and night-time SBP drops (<110, 100, 90, 80 mmHg) were assessed. Hypotensive susceptibility was defined likely or possible for cut-offs achieving the highest sensitivity among those with specificity > 90% and 80–90%, respectively. Findings were validated in an independent sample. Results: In the Derivation cohort, daytime SBP drops were significantly more common in 158 syncope patients than 329 controls. One or more daytime drop < 90 mmHg provided the best diagnostic yield (91% specificity, 32% sensitivity, Odds Ratio [OR] = 4.6, p = 0.001). Two or more-daytime drops < 100 mmHg achieved 84% specificity and 40% sensitivity (OR = 3.5, p = 0.001). Results were confirmed in the Validation cohort: one or more daytime SBP drop < 90 mmHg provided 94% specificity and 29% sensitivity (OR = 6.2, p < 0.001), while two or more daytime SBP drops < 100 mmHg achieved 83% specificity and 35% sensitivity (OR = 3.5, p < 0.001) Conclusions: SBP drops during ABPM are more common in reflex syncope patients than in controls. Cut-off values that may be applied in clinical practice are defined. This study expands the current indications for ABPM to patients with reflex syncope. … (more)
- Is Part Of:
- Journal of hypertension. Volume 40(2022)Supplement 1
- Journal:
- Journal of hypertension
- Issue:
- Volume 40(2022)Supplement 1
- Issue Display:
- Volume 40, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 40
- Issue:
- 1
- Issue Sort Value:
- 2022-0040-0001-0000
- Page Start:
- e10
- Page End:
- Publication Date:
- 2022-06
- Subjects:
- Hypertension -- Periodicals
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.lww.com/jhypertension/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004872-000000000-00000 ↗
http://www.jhypertension.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/01.hjh.0000835388.77387.e5 ↗
- Languages:
- English
- ISSNs:
- 1473-5598
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5004.510000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21969.xml