How Are We Monitoring Brain Injuries in Patients With Left Ventricular Assist Device? A Systematic Review of Literature. Issue 2 (February 2021)
- Record Type:
- Journal Article
- Title:
- How Are We Monitoring Brain Injuries in Patients With Left Ventricular Assist Device? A Systematic Review of Literature. Issue 2 (February 2021)
- Main Title:
- How Are We Monitoring Brain Injuries in Patients With Left Ventricular Assist Device? A Systematic Review of Literature
- Authors:
- Fan, Tracey H.
Hassett, Catherine E.
Migdady, Ibrahim
Price, Carrie
Choi, Chun Woo
Katzan, Irene
Cho, Sung-Min - Abstract:
- Abstract : Despite the common occurrence of brain injury in patients with left ventricular assist device (LVAD), optimal neuromonitoring methods are unknown. A systematic review of PubMed and six electronic databases from inception was conducted until June 5, 2019. Studies reporting methods of neuromonitoring while on LVAD were extracted. Of 5, 190 records screened, 37 studies met the inclusion criteria. The neuromonitoring methods include Transcranial Doppler ultrasound for emboli monitoring (TCD-e) (n = 13) and cerebral autoregulation (n = 3), computed tomography and magnetic resonance imaging (n = 9), serum biomarkers (n = 7), carotid ultrasound (n = 3), and near-infrared spectroscopy (n = 2). Of 421 patients with TCD-e, thromboembolic events (TEs) were reported in 79 patients (20%) and microembolic signals (MES) were detected in 105 patients (27%). Ischemic stroke was more prevalent in patients with MES compared to patients without MES (43% vs. 13%, p < 0.001). Carotid ultrasound for assessing carotid stenosis was unreliable after LVAD implantation. Elevated lactate dehydrogenase (LDH) levels were associated with TEs. Significant heterogeneity exists in timing, frequency, and types of neuromonitoring tools. TCD-e and serial LDH levels appeared to have potential for assessing the risk of ischemic stroke. Future prospective research incorporating protocolized TCD-e and LDH may assist in monitoring adverse events in patients with LVAD. Abstract : Supplemental DigitalAbstract : Despite the common occurrence of brain injury in patients with left ventricular assist device (LVAD), optimal neuromonitoring methods are unknown. A systematic review of PubMed and six electronic databases from inception was conducted until June 5, 2019. Studies reporting methods of neuromonitoring while on LVAD were extracted. Of 5, 190 records screened, 37 studies met the inclusion criteria. The neuromonitoring methods include Transcranial Doppler ultrasound for emboli monitoring (TCD-e) (n = 13) and cerebral autoregulation (n = 3), computed tomography and magnetic resonance imaging (n = 9), serum biomarkers (n = 7), carotid ultrasound (n = 3), and near-infrared spectroscopy (n = 2). Of 421 patients with TCD-e, thromboembolic events (TEs) were reported in 79 patients (20%) and microembolic signals (MES) were detected in 105 patients (27%). Ischemic stroke was more prevalent in patients with MES compared to patients without MES (43% vs. 13%, p < 0.001). Carotid ultrasound for assessing carotid stenosis was unreliable after LVAD implantation. Elevated lactate dehydrogenase (LDH) levels were associated with TEs. Significant heterogeneity exists in timing, frequency, and types of neuromonitoring tools. TCD-e and serial LDH levels appeared to have potential for assessing the risk of ischemic stroke. Future prospective research incorporating protocolized TCD-e and LDH may assist in monitoring adverse events in patients with LVAD. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- ASAIO journal. Volume 67:Issue 2(2021)
- Journal:
- ASAIO journal
- Issue:
- Volume 67:Issue 2(2021)
- Issue Display:
- Volume 67, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 67
- Issue:
- 2
- Issue Sort Value:
- 2021-0067-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- LVAD -- ischemic stroke -- hemorrhagic stroke -- neuromonitoring -- neurologic monitoring
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000001204 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21957.xml