Comparison of Acetabular Measurements Between 2 Validated Software Programs Used in Hip Preservation Surgery. Issue 10 (August 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of Acetabular Measurements Between 2 Validated Software Programs Used in Hip Preservation Surgery. Issue 10 (August 2022)
- Main Title:
- Comparison of Acetabular Measurements Between 2 Validated Software Programs Used in Hip Preservation Surgery
- Authors:
- Laboudie, Pierre
Fischman, Daniel
Speirs, Andrew D.
Salih, Saif
Holc, Fernando
Beaule, Paul E.
Witt, Johan D.
Grammatopoulos, George - Abstract:
- Background: Validated software tools (Clinical Graphics [CG] and Hip 2 Norm) permit measurement of the percentage of femoral head coverage (%FHC), which aids in morphological classification and prediction of outcome after hip preservation surgery. Purpose: (1) To assess whether acetabular parameter measurements determined from 2 commonly used software systems are comparable. (2) To determine which parameters influence the correlation or differences between software outputs and measurements. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The study included 69 patients (90 hips) who underwent periacetabular osteotomy and had comprehensive preoperative imaging available. Lateral center-edge angle (LCEA), acetabular index (AI), and %FHC were determined using 3-dimensional computed tomography (CT) measurements by CG and Hip 2 Norm software. Images of 18 pelvises were segmented to determine spinopelvic parameters and subtended acetabular angles. Between-group measurements were compared using correlation coefficients and Bland-Altman analyses. The difference in the outputs of the 2 programs was defined as delta (Δ). Radiographic parameters were tested to assess whether they were responsible for differences in %FHC between software programs. Results: Strong correlations between LCEA (ρ = 0.862) and AI (ρ = 0.825) measurements were seen between the Hip 2 Norm and CG programs. However, weak correlation was seen in the estimate of %FHC (ρ = 0.358), with theBackground: Validated software tools (Clinical Graphics [CG] and Hip 2 Norm) permit measurement of the percentage of femoral head coverage (%FHC), which aids in morphological classification and prediction of outcome after hip preservation surgery. Purpose: (1) To assess whether acetabular parameter measurements determined from 2 commonly used software systems are comparable. (2) To determine which parameters influence the correlation or differences between software outputs and measurements. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The study included 69 patients (90 hips) who underwent periacetabular osteotomy and had comprehensive preoperative imaging available. Lateral center-edge angle (LCEA), acetabular index (AI), and %FHC were determined using 3-dimensional computed tomography (CT) measurements by CG and Hip 2 Norm software. Images of 18 pelvises were segmented to determine spinopelvic parameters and subtended acetabular angles. Between-group measurements were compared using correlation coefficients and Bland-Altman analyses. The difference in the outputs of the 2 programs was defined as delta (Δ). Radiographic parameters were tested to assess whether they were responsible for differences in %FHC between software programs. Results: Strong correlations between LCEA (ρ = 0.862) and AI (ρ = 0.825) measurements were seen between the Hip 2 Norm and CG programs. However, weak correlation was seen in the estimate of %FHC (ρ = 0.358), with the presence of a systematic error. Hip 2 Norm consistently produced lower anterior, posterior, and total %FHC values than CG. The %FHC determined by CG, but not Hip 2 Norm, correlated with acetabular subtended angles ( P < .05). Pelvic tilt measured on CT did not correlate with pelvic tilt estimated by Hip 2 Norm ( P = .56), and ΔPelvicTilt strongly correlated with the difference in %FHC by the 2 software programs (ρ = 0.63; P = .005), pelvic incidence (ρ = 0.73; P < .001), and pelvic tilt (ρ = −0.91; P < .001) as per CT. Conclusion: The correlation of %FHC between Hip 2 Norm and CG was weak (ρ = 0.358). The difference in measurements of %FHC correlated with ΔPelvicTilt. The %FHC determined by CG strongly correlated with the segmented acetabular subtended angles and thus more likely reflected true values. Hip preservation surgeons should be aware of these measurement differences because %FHC is important in the diagnosis and prognosis of acetabular dysplasia. … (more)
- Is Part Of:
- American journal of sports medicine. Volume 50:Issue 10(2022)
- Journal:
- American journal of sports medicine
- Issue:
- Volume 50:Issue 10(2022)
- Issue Display:
- Volume 50, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 50
- Issue:
- 10
- Issue Sort Value:
- 2022-0050-0010-0000
- Page Start:
- 2637
- Page End:
- 2646
- Publication Date:
- 2022-08
- Subjects:
- hip -- acetabular dysplasia -- femoral head coverage
Sports medicine -- Periodicals
Sports injuries -- Periodicals
Orthopedic surgery -- Periodicals
617.102705 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0363-5465 ↗
http://ajs.sagepub.com ↗
http://www.ajsm.org ↗
http://www.sagepub.com ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1177/03635465221109240 ↗
- Languages:
- English
- ISSNs:
- 0363-5465
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21950.xml