Towards range-guidance in proton therapy to detect organ motion-induced dose degradations. (1st March 2022)
- Record Type:
- Journal Article
- Title:
- Towards range-guidance in proton therapy to detect organ motion-induced dose degradations. (1st March 2022)
- Main Title:
- Towards range-guidance in proton therapy to detect organ motion-induced dose degradations
- Authors:
- Busch, Kia
Andersen, Andreas G
Petersen, Jørgen B B
Petersen, Stine E
Rønde, Heidi S
Bentzen, Lise
Pilskog, Sara
Skyt, Peter
Nørrevang, Ole
Muren, Ludvig P - Abstract:
- Abstract: Introduction. Internal organ motion and deformations may cause dose degradations in proton therapy (PT) that are challenging to resolve using conventional image-guidance strategies. This study aimed to investigate the potential of range guidance using water-equivalent path length (WEPL) calculations to detect dose degradations occurring in PT. Materials and methods . Proton ranges were estimated using WEPL calculations. Field-specific isodose surfaces in the planning CT (pCT), from robustly optimised five-field proton plans (opposing lateral and three posterior/posterior oblique beams) for locally advanced prostate cancer patients, were used as starting points. WEPLs to each point on the field-specific isodoses in the pCT were calculated. The corresponding range for each point was found in the repeat CTs (rCTs). The spatial agreement between the resulting surfaces in the rCTs (hereafter referred to as iso-WEPLs) and the isodoses re-calculated in rCTs was evaluated for different dose levels and Hausdorff thresholds (2–5 mm). Finally, the sensitivity and specificity of detecting target dose degradation (V95% < 95%) using spatial agreement measures between the iso-WEPLs and isodoses in the pCT was evaluated. Results . The spatial agreement between the iso-WEPLs and isodoses in the rCTs depended on the Hausdorff threshold. The agreement was 65%–88% for a 2 mm threshold, 83%–96% for 3 mm, 90%–99% for 4 mm, and 94%–99% for 5 mm, across all fields and isodose levels.Abstract: Introduction. Internal organ motion and deformations may cause dose degradations in proton therapy (PT) that are challenging to resolve using conventional image-guidance strategies. This study aimed to investigate the potential of range guidance using water-equivalent path length (WEPL) calculations to detect dose degradations occurring in PT. Materials and methods . Proton ranges were estimated using WEPL calculations. Field-specific isodose surfaces in the planning CT (pCT), from robustly optimised five-field proton plans (opposing lateral and three posterior/posterior oblique beams) for locally advanced prostate cancer patients, were used as starting points. WEPLs to each point on the field-specific isodoses in the pCT were calculated. The corresponding range for each point was found in the repeat CTs (rCTs). The spatial agreement between the resulting surfaces in the rCTs (hereafter referred to as iso-WEPLs) and the isodoses re-calculated in rCTs was evaluated for different dose levels and Hausdorff thresholds (2–5 mm). Finally, the sensitivity and specificity of detecting target dose degradation (V95% < 95%) using spatial agreement measures between the iso-WEPLs and isodoses in the pCT was evaluated. Results . The spatial agreement between the iso-WEPLs and isodoses in the rCTs depended on the Hausdorff threshold. The agreement was 65%–88% for a 2 mm threshold, 83%–96% for 3 mm, 90%–99% for 4 mm, and 94%–99% for 5 mm, across all fields and isodose levels. Minor differences were observed between the different isodose levels investigated. Target dose degradations were detected with 82%–100% sensitivity and 75%–80% specificity using a 2 mm Hausdorff threshold for the lateral fields. Conclusion . Iso-WEPLs were comparable to isodoses re-calculated in the rCTs. The proposed strategy could detect target dose degradations occurring in the rCTs and could be an alternative to a fully-fledged dose re-calculation to detect anatomical variations severely influencing the proton range. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 8:Number 2(2022)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 8:Number 2(2022)
- Issue Display:
- Volume 8, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 2
- Issue Sort Value:
- 2022-0008-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03-01
- Subjects:
- range-guidance -- water equivalent path length -- advanced prostate cancer -- proton therapy -- inter-fractional motion
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/ac5151 ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21945.xml