Measurement uncertainty quantification for myocardial perfusion using cardiac positron emission tomography imaging. (1st June 2022)
- Record Type:
- Journal Article
- Title:
- Measurement uncertainty quantification for myocardial perfusion using cardiac positron emission tomography imaging. (1st June 2022)
- Main Title:
- Measurement uncertainty quantification for myocardial perfusion using cardiac positron emission tomography imaging
- Authors:
- Partarrieu, Ignacio X
Jagan, Kavya
Fenwick, Andrew
Han, Chunlei
Siekkinen, Reetta
Teuho, Jarmo
Saraste, Antti
Smith, Nadia A S - Abstract:
- Abstract: Perfusion, the flow of blood, and hence oxygen, is essential to the functioning of the heart. Reduced perfusion (or ischemia), is a reliable indicator of the presence of significant obstructive coronary artery disease (CAD), which is one of the biggest causes of death in Europe. Myocardial perfusion imaging is a non-invasive technique used in the diagnosis, management and prognosis of CAD and is a key component in the triage of patients into treatment and non-treatment groups. Cardiac positron emission tomography (PET) is an imaging technique with high sensitivity and specificity to CAD, however perfusion measurements are difficult to calibrate against a common reference standard, and confidence in them is generally not quantified in terms of measurement uncertainty. There are a number of steps involved in measuring perfusion using cardiac PET—from patient preparation to data analysis—each associated with potential sources of uncertainty. The absence of measurement uncertainty quantification can lead to inaccuracies in measurement results, a lack of comparability between devices or scanning facilities, and is likely to be detrimental to a decision-making process. In this paper, we identify some of the sources of measurement uncertainty in the cardiac PET perfusion measurement pipeline. We assess their relative contribution by performing a sensitivity analysis using experimental data of a flow phantom acquired on a PET scanner. The results of this analysis willAbstract: Perfusion, the flow of blood, and hence oxygen, is essential to the functioning of the heart. Reduced perfusion (or ischemia), is a reliable indicator of the presence of significant obstructive coronary artery disease (CAD), which is one of the biggest causes of death in Europe. Myocardial perfusion imaging is a non-invasive technique used in the diagnosis, management and prognosis of CAD and is a key component in the triage of patients into treatment and non-treatment groups. Cardiac positron emission tomography (PET) is an imaging technique with high sensitivity and specificity to CAD, however perfusion measurements are difficult to calibrate against a common reference standard, and confidence in them is generally not quantified in terms of measurement uncertainty. There are a number of steps involved in measuring perfusion using cardiac PET—from patient preparation to data analysis—each associated with potential sources of uncertainty. The absence of measurement uncertainty quantification can lead to inaccuracies in measurement results, a lack of comparability between devices or scanning facilities, and is likely to be detrimental to a decision-making process. In this paper, we identify some of the sources of measurement uncertainty in the cardiac PET perfusion measurement pipeline. We assess their relative contribution by performing a sensitivity analysis using experimental data of a flow phantom acquired on a PET scanner. The results of this analysis will inform users of how parameter choices in their imaging pipeline affect the output of their measurements, and serves as a starting point to develop an uncertainty quantification method. … (more)
- Is Part Of:
- Measurement science & technology. Volume 33:Number 6(2022)
- Journal:
- Measurement science & technology
- Issue:
- Volume 33:Number 6(2022)
- Issue Display:
- Volume 33, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 6
- Issue Sort Value:
- 2022-0033-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-06-01
- Subjects:
- cardiac PET perfusion -- design of experiments -- sensitivity analysis -- sources of measurement uncertainty -- flow phantom
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/ac58e3 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21956.xml