Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial. Issue 10080 (29th April 2017)
- Record Type:
- Journal Article
- Title:
- Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial. Issue 10080 (29th April 2017)
- Main Title:
- Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial
- Authors:
- Brocklehurst, Peter
Field, David
Greene, Keith
Juszczak, Ed
Keith, Robert
Kenyon, Sara
Linsell, Louise
Mabey, Christopher
Newburn, Mary
Plachcinski, Rachel
Quigley, Maria
Schroeder, Elizabeth
Steer, Philip - Abstract:
- Summary: Background: Continuous electronic fetal heart-rate monitoring is widely used during labour, and computerised interpretation could increase its usefulness. We aimed to establish whether the addition of decision-support software to assist in the interpretation of cardiotocographs affected the number of poor neonatal outcomes. Methods: In this unmasked randomised controlled trial, we recruited women in labour aged 16 years or older having continuous electronic fetal monitoring, with a singleton or twin pregnancy, and at 35 weeks' gestation or more at 24 maternity units in the UK and Ireland. They were randomly assigned (1:1) to decision support with the INFANT system or no decision support via a computer-generated stratified block randomisation schedule. The primary outcomes were poor neonatal outcome (intrapartum stillbirth or early neonatal death excluding lethal congenital anomalies, or neonatal encephalopathy, admission to the neonatal unit within 24 h for ≥48 h with evidence of feeding difficulties, respiratory illness, or encephalopathy with evidence of compromise at birth), and developmental assessment at age 2 years in a subset of surviving children. Analyses were done by intention to treat. This trial is completed and is registered with the ISRCTN Registry, number 98680152. Findings: Between Jan 6, 2010, and Aug 31, 2013, 47 062 women were randomly assigned (23 515 in the decision-support group and 23 547 in the no-decision-support group) and 46 042 wereSummary: Background: Continuous electronic fetal heart-rate monitoring is widely used during labour, and computerised interpretation could increase its usefulness. We aimed to establish whether the addition of decision-support software to assist in the interpretation of cardiotocographs affected the number of poor neonatal outcomes. Methods: In this unmasked randomised controlled trial, we recruited women in labour aged 16 years or older having continuous electronic fetal monitoring, with a singleton or twin pregnancy, and at 35 weeks' gestation or more at 24 maternity units in the UK and Ireland. They were randomly assigned (1:1) to decision support with the INFANT system or no decision support via a computer-generated stratified block randomisation schedule. The primary outcomes were poor neonatal outcome (intrapartum stillbirth or early neonatal death excluding lethal congenital anomalies, or neonatal encephalopathy, admission to the neonatal unit within 24 h for ≥48 h with evidence of feeding difficulties, respiratory illness, or encephalopathy with evidence of compromise at birth), and developmental assessment at age 2 years in a subset of surviving children. Analyses were done by intention to treat. This trial is completed and is registered with the ISRCTN Registry, number 98680152. Findings: Between Jan 6, 2010, and Aug 31, 2013, 47 062 women were randomly assigned (23 515 in the decision-support group and 23 547 in the no-decision-support group) and 46 042 were analysed (22 987 in the decision-support group and 23 055 in the no-decision-support group). We noted no difference in the incidence of poor neonatal outcome between the groups—172 (0·7%) babies in the decision-support group compared with 171 (0·7%) babies in the no-decision-support group (adjusted risk ratio 1·01, 95% CI 0·82–1·25). At 2 years, no significant differences were noted in terms of developmental assessment. Interpretation: Use of computerised interpretation of cardiotocographs in women who have continuous electronic fetal monitoring in labour does not improve clinical outcomes for mothers or babies. Funding: National Institute for Health Research. … (more)
- Is Part Of:
- Lancet. Volume 389:Issue 10080(2017)
- Journal:
- Lancet
- Issue:
- Volume 389:Issue 10080(2017)
- Issue Display:
- Volume 389, Issue 10080 (2017)
- Year:
- 2017
- Volume:
- 389
- Issue:
- 10080
- Issue Sort Value:
- 2017-0389-10080-0000
- Page Start:
- 1719
- Page End:
- 1729
- Publication Date:
- 2017-04-29
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Medicine
Electronic journals
Periodicals
610.5 - Journal URLs:
- http://www.thelancet.com/ ↗
http://www.sciencedirect.com/science/journal/01406736 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/S0140-6736(17)30568-8 ↗
- Languages:
- English
- ISSNs:
- 0140-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5146.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21931.xml