A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery. (31st July 2012)
- Record Type:
- Journal Article
- Title:
- A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery. (31st July 2012)
- Main Title:
- A Comparison of Third-Generation Semi-Invasive Arterial Waveform Analysis with Thermodilution in Patients Undergoing Coronary Surgery
- Authors:
- Broch, Ole
Renner, Jochen
Gruenewald, Matthias
Meybohm, Patrick
Schöttler, Jan
Steinfath, Markus
Malbrain, Manu
Bein, Berthold - Other Names:
- Alvarez J. Academic Editor.
Misumi I. Academic Editor.
Skalidis E. Academic Editor.
Vallejo M. C. Academic Editor. - Abstract:
- Abstract : Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary bypass (CPB), respectively. Each patient was monitored with a central venous line, the PiCCO system, and the FloTrac/Vigileo-system. Measurements included CI derived by transpulmonary thermodilution and uncalibrated semi-invasive pulse contour analysis. Percentage changes of CI were calculated. There was a moderate, but significant correlation between pulse contour CI and thermodilution CI both before (r 2 = 0.72, P < 0.0001 ) and after (r 2 = 0.62, P < 0.0001 ) CPB, with a percentage error of 31% and 25%, respectively. Changes in pulse contour CI showed a significant correlation with changes in thermodilution CI both before (r 2 = 0.52, P < 0.0001 ) and after (r 2 = 0.67, P < 0.0001 ) CPB. Our findings demonstrated that uncalibrated semi-invasive monitoring system was able to reliably measure CI compared with transpulmonary thermodilution in patients undergoing elective coronary surgery. Furthermore, the semi-invasive monitoring device was able to track haemodynamic changes and trends.
- Is Part Of:
- TheScientificWorldjournal. Volume 2012(2012)
- Journal:
- TheScientificWorldjournal
- Issue:
- Volume 2012(2012)
- Issue Display:
- Volume 2012, Issue 2012 (2012)
- Year:
- 2012
- Volume:
- 2012
- Issue:
- 2012
- Issue Sort Value:
- 2012-2012-2012-0000
- Page Start:
- Page End:
- Publication Date:
- 2012-07-31
- Subjects:
- Science -- Periodicals
Technology -- Periodicals
Medicine -- Periodicals
505 - Journal URLs:
- https://www.hindawi.com/journals/tswj/biblio/ ↗
- DOI:
- 10.1100/2012/451081 ↗
- Languages:
- English
- ISSNs:
- 2356-6140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 21950.xml