Bone material analogues for PET/MRI phantoms. Issue 5 (13th March 2020)
- Record Type:
- Journal Article
- Title:
- Bone material analogues for PET/MRI phantoms. Issue 5 (13th March 2020)
- Main Title:
- Bone material analogues for PET/MRI phantoms
- Authors:
- Chandramohan, Dharshan
Cao, Peng
Han, Misung
An, Hongyu
Sunderland, John J.
Kinahan, Paul E.
Laforest, Richard
Hope, Thomas A.
Larson, Peder E. Z. - Other Names:
- El Naqa Issam guestEditor.
Das Shiva K. guestEditor. - Abstract:
- Abstract : Purpose: To develop bone material analogues that can be used in construction of phantoms for simultaneous PET/MRI systems. Methods: Plaster was used as the basis for the bone material analogues tested in this study. It was mixed with varying concentrations of an iodinated CT contrast, a gadolinium‐based MR contrast agent, and copper sulfate to modulate the attenuation properties and MRI properties (T1 and T2*). Attenuation was measured with CT and 68 Ge transmission scans, and MRI properties were measured with quantitative ultrashort echo time pulse sequences. A proof‐of‐concept skull was created by plaster casting. Results: Undoped plaster has a 511 keV attenuation coefficient (~0.14 cm −1 ) similar to cortical bone (0.10–0.15 cm −1 ), but slightly longer T1 (~500 ms) and T2* (~1.2 ms) MR parameters compared to bone (T1 ~ 300 ms, T2* ~ 0.4 ms). Doping with the iodinated agent resulted in increased attenuation with minimal perturbation to the MR parameters. Doping with a gadolinium chelate greatly reduced T1 and T2*, resulting in extremely short T1 values when the target T2* values were reached, while the attenuation coefficient was unchanged. Doping with copper sulfate was more selective for T2* shortening and achieved comparable T1 and T2* values to bone (after 1 week of drying), while the attenuation coefficient was unchanged. Conclusions: Plaster doped with copper sulfate is a promising bone material analogue for a PET/MRI phantom, mimicking the MR propertiesAbstract : Purpose: To develop bone material analogues that can be used in construction of phantoms for simultaneous PET/MRI systems. Methods: Plaster was used as the basis for the bone material analogues tested in this study. It was mixed with varying concentrations of an iodinated CT contrast, a gadolinium‐based MR contrast agent, and copper sulfate to modulate the attenuation properties and MRI properties (T1 and T2*). Attenuation was measured with CT and 68 Ge transmission scans, and MRI properties were measured with quantitative ultrashort echo time pulse sequences. A proof‐of‐concept skull was created by plaster casting. Results: Undoped plaster has a 511 keV attenuation coefficient (~0.14 cm −1 ) similar to cortical bone (0.10–0.15 cm −1 ), but slightly longer T1 (~500 ms) and T2* (~1.2 ms) MR parameters compared to bone (T1 ~ 300 ms, T2* ~ 0.4 ms). Doping with the iodinated agent resulted in increased attenuation with minimal perturbation to the MR parameters. Doping with a gadolinium chelate greatly reduced T1 and T2*, resulting in extremely short T1 values when the target T2* values were reached, while the attenuation coefficient was unchanged. Doping with copper sulfate was more selective for T2* shortening and achieved comparable T1 and T2* values to bone (after 1 week of drying), while the attenuation coefficient was unchanged. Conclusions: Plaster doped with copper sulfate is a promising bone material analogue for a PET/MRI phantom, mimicking the MR properties (T1 and T2*) and 511 keV attenuation coefficient of human cortical bone. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 5(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 5(2020)
- Issue Display:
- Volume 47, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 5
- Issue Sort Value:
- 2020-0047-0005-0000
- Page Start:
- 2161
- Page End:
- 2170
- Publication Date:
- 2020-03-13
- Subjects:
- attenuation correction -- bone materials -- doped plaster -- PET/MRI
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14079 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21898.xml