Analytic Sensitivity of 3 Nucleic Acid Detection Assays in Diagnosis of SARS-CoV-2 Infection. (27th November 2020)
- Record Type:
- Journal Article
- Title:
- Analytic Sensitivity of 3 Nucleic Acid Detection Assays in Diagnosis of SARS-CoV-2 Infection. (27th November 2020)
- Main Title:
- Analytic Sensitivity of 3 Nucleic Acid Detection Assays in Diagnosis of SARS-CoV-2 Infection
- Authors:
- Sieker, Jakob T
Horowitz, Coby
Hu, Cheng-Tsung K
Lacombe-Daphnis, Meriane
Chirokas, Bernadette
Pina, Coteia
Heger, Nicholas E
Rabson, Arthur R
Zhou, Ming
Bogen, Steven A
Horowitz, Gary L - Abstract:
- Abstract: Background: Detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by reverse transcription PCR is the primary method to diagnose coronavirus disease 2019 (COVID-19). However, the analytic sensitivity required is not well defined and it is unclear how available assays compare. Methods: For the Abbott RealTime SARS-CoV-2 assay (m2000; Abbott Molecular), we determined that it could detect viral concentrations as low as 26 copies/mL, we defined the relationship between cycle number and viral concentrations, and we tested naso- and oropharyngeal swab specimens from 8538 consecutive individuals. Using the m2000 as a reference assay method, we described the distribution of viral concentrations in these patients. We then used selected clinical specimens to determine the positive percent agreement of 2 other assays with more rapid turnaround times [Cepheid Xpert Xpress (GeneXpert; Cepheid); n = 27] and a laboratory developed test on the Luminex ARIES system [ARIES LDT (Luminex); n = 50] as a function of virus concentrations, from which we projected their false-negative rates in our patient population. Results: SARS-CoV-2 was detected in 27% (95% CI: 26%–28%) of all specimens. Estimated viral concentrations were widely distributed, and 17% (95% CI: 16%–19%) of positive individuals had viral concentrations <845 copies/mL. Positive percent agreement was strongly related to viral concentration, and reliable detection (i.e., ≥95%) was observed atAbstract: Background: Detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by reverse transcription PCR is the primary method to diagnose coronavirus disease 2019 (COVID-19). However, the analytic sensitivity required is not well defined and it is unclear how available assays compare. Methods: For the Abbott RealTime SARS-CoV-2 assay (m2000; Abbott Molecular), we determined that it could detect viral concentrations as low as 26 copies/mL, we defined the relationship between cycle number and viral concentrations, and we tested naso- and oropharyngeal swab specimens from 8538 consecutive individuals. Using the m2000 as a reference assay method, we described the distribution of viral concentrations in these patients. We then used selected clinical specimens to determine the positive percent agreement of 2 other assays with more rapid turnaround times [Cepheid Xpert Xpress (GeneXpert; Cepheid); n = 27] and a laboratory developed test on the Luminex ARIES system [ARIES LDT (Luminex); n = 50] as a function of virus concentrations, from which we projected their false-negative rates in our patient population. Results: SARS-CoV-2 was detected in 27% (95% CI: 26%–28%) of all specimens. Estimated viral concentrations were widely distributed, and 17% (95% CI: 16%–19%) of positive individuals had viral concentrations <845 copies/mL. Positive percent agreement was strongly related to viral concentration, and reliable detection (i.e., ≥95%) was observed at concentrations >100 copies/mL for the GeneXpert but not the ARIES LDT, corresponding to projected false-negative rates of 4% (95% CI: 0%–21%) and 27% (95% CI: 11%–46%), respectively. Conclusions: Substantial proportions of clinical specimens have low to moderate viral concentrations and may be missed by methods with less analytic sensitivity. … (more)
- Is Part Of:
- Journal of applied laboratory medicine. Volume 6:Number 2(2021)
- Journal:
- Journal of applied laboratory medicine
- Issue:
- Volume 6:Number 2(2021)
- Issue Display:
- Volume 6, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 2
- Issue Sort Value:
- 2021-0006-0002-0000
- Page Start:
- 421
- Page End:
- 428
- Publication Date:
- 2020-11-27
- Subjects:
- Clinical chemistry -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.0756 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/jalm ↗ - DOI:
- 10.1093/jalm/jfaa187 ↗
- Languages:
- English
- ISSNs:
- 2576-9456
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21893.xml