Comparative Analysis of Tear Proteins in Keratoconic Scleral Lens Wearers with Variation in Limbal Clearance. Issue 2 (February 2021)
- Record Type:
- Journal Article
- Title:
- Comparative Analysis of Tear Proteins in Keratoconic Scleral Lens Wearers with Variation in Limbal Clearance. Issue 2 (February 2021)
- Main Title:
- Comparative Analysis of Tear Proteins in Keratoconic Scleral Lens Wearers with Variation in Limbal Clearance
- Authors:
- Yeung, Debby
Murphy, Paul J.
Sorbara, Luigina - Abstract:
- Abstract : SIGNIFICANCE: Cytokine and protease analysis revealed relative changes in the post-lens tear film of scleral lenses with low and high limbal clearances. Results from this study indicate that midperipheral lens fit is an important fitting feature that can impact the inflammatory response of a keratoconic eye. PURPOSE: The purpose of this study was to investigate changes in levels of inflammatory mediators in the post-lens tear film of keratoconic scleral lens wearers with varying limbal clearance designs. METHODS: Twenty-two keratoconic eyes were fitted with two sets of scleral lenses that were consistent in lens diameter and central sagittal depth but varied in limbal clearance by approximately 50 μm. Lenses were worn in a randomly assigned order for a 2-week period each. At each follow-up visit, immediately after lens removal, tear samples were collected with a microcapillary tube (10 μL, 0.5 mm in diameter) from the bowl of the inverted scleral lens. Tear cytokine and protease analysis was performed using a multiplex electrochemiluminescent array (Meso Scale Discovery, Rockville, MD) instrument. Levels of interleukins 1, 6, and 8; tumor necrosis factor α; and matrix metalloproteinases 1 and 9 were compared and analyzed. RESULTS: Levels of interleukin 1β, tumor necrosis factor α, and matrix metalloproteinase 1 increased with high limbal clearance ( P = .01, .006, and .02, respectively). No change in interleukins 6 and 8 levels was found ( P > .05). A decrease inAbstract : SIGNIFICANCE: Cytokine and protease analysis revealed relative changes in the post-lens tear film of scleral lenses with low and high limbal clearances. Results from this study indicate that midperipheral lens fit is an important fitting feature that can impact the inflammatory response of a keratoconic eye. PURPOSE: The purpose of this study was to investigate changes in levels of inflammatory mediators in the post-lens tear film of keratoconic scleral lens wearers with varying limbal clearance designs. METHODS: Twenty-two keratoconic eyes were fitted with two sets of scleral lenses that were consistent in lens diameter and central sagittal depth but varied in limbal clearance by approximately 50 μm. Lenses were worn in a randomly assigned order for a 2-week period each. At each follow-up visit, immediately after lens removal, tear samples were collected with a microcapillary tube (10 μL, 0.5 mm in diameter) from the bowl of the inverted scleral lens. Tear cytokine and protease analysis was performed using a multiplex electrochemiluminescent array (Meso Scale Discovery, Rockville, MD) instrument. Levels of interleukins 1, 6, and 8; tumor necrosis factor α; and matrix metalloproteinases 1 and 9 were compared and analyzed. RESULTS: Levels of interleukin 1β, tumor necrosis factor α, and matrix metalloproteinase 1 increased with high limbal clearance ( P = .01, .006, and .02, respectively). No change in interleukins 6 and 8 levels was found ( P > .05). A decrease in matrix metalloproteinase 9 was noted in post-lens tear film of scleral lenses with high limbal clearance ( P = .10). DISCUSSION: Relative changes in the cytokine and protease levels were found when comparing low and high limbal clearance, indicating that the midperipheral lens fit is an important feature that can impact the inflammatory response of the keratoconic eye. … (more)
- Is Part Of:
- Optometry and vision science. Volume 98:Issue 2(2021)
- Journal:
- Optometry and vision science
- Issue:
- Volume 98:Issue 2(2021)
- Issue Display:
- Volume 98, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 98
- Issue:
- 2
- Issue Sort Value:
- 2021-0098-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000001645 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 21895.xml