Meta‐analysis of catheter ablation in patients with post‐infarct cardiomyopathy undergoing defibrillator implantation. Issue 1 (13th November 2020)
- Record Type:
- Journal Article
- Title:
- Meta‐analysis of catheter ablation in patients with post‐infarct cardiomyopathy undergoing defibrillator implantation. Issue 1 (13th November 2020)
- Main Title:
- Meta‐analysis of catheter ablation in patients with post‐infarct cardiomyopathy undergoing defibrillator implantation
- Authors:
- Kheiri, Babikir
Simpson, Timothy F.
Nazer, Babak - Abstract:
- Abstract: Background: Patients with post‐infarct cardiomyopathy and ventricular arrhythmias (VT) necessitating implantable cardioverter defibrillators (ICD) are at risk of recurrent shocks with increased morbidity. Methods: A comprehensive search of electronic databases for all randomized clinical trials that evaluated the role of catheter ablation as a preventive strategy at the time of secondary prevention ICD implantation was performed. We calculated hazard ratios (HR) and 95% confidence intervals (CI) using random‐effects model. Results: Four trials were identified with a total of 505 patients (average age 66.4 ± 9.0 years; 87.7% were male). Preventive ablation was associated with a significant reduction in appropriate device therapies (shocks and/or anti‐tachycardia therapy) (HR = 0.62; 95% CI = 0.46‐0.82; P < .01), sustained VT (HR = 0.74; 95% CI = 0.55‐0.99; P = .04) compared to control. There were no differences in inappropriate device shocks (HR = 0.80; 95% CI = 0.38‐1.71), all‐cause death (HR = 0.93; 95% CI = 0.53‐1.64), cardiac death (HR = 0.63; 95% CI = 0.29‐1.36), arrhythmic death (HR = 0.26; 95% CI = 0.05‐1.31), or cardiac hospitalization (HR = 0.79; 95% CI = 0.57‐1.11) between strategies. Preventive ablation was associated with improved SF‐36 physical component (mean difference = 2.81; 95% CI‐0.53‐5.10; P = .02), but not the mental component (mean difference = 1.30; 95% CI = ‐2.06‐4.66). Conclusion: Among patients with post‐infarct cardiomyopathy and VT,Abstract: Background: Patients with post‐infarct cardiomyopathy and ventricular arrhythmias (VT) necessitating implantable cardioverter defibrillators (ICD) are at risk of recurrent shocks with increased morbidity. Methods: A comprehensive search of electronic databases for all randomized clinical trials that evaluated the role of catheter ablation as a preventive strategy at the time of secondary prevention ICD implantation was performed. We calculated hazard ratios (HR) and 95% confidence intervals (CI) using random‐effects model. Results: Four trials were identified with a total of 505 patients (average age 66.4 ± 9.0 years; 87.7% were male). Preventive ablation was associated with a significant reduction in appropriate device therapies (shocks and/or anti‐tachycardia therapy) (HR = 0.62; 95% CI = 0.46‐0.82; P < .01), sustained VT (HR = 0.74; 95% CI = 0.55‐0.99; P = .04) compared to control. There were no differences in inappropriate device shocks (HR = 0.80; 95% CI = 0.38‐1.71), all‐cause death (HR = 0.93; 95% CI = 0.53‐1.64), cardiac death (HR = 0.63; 95% CI = 0.29‐1.36), arrhythmic death (HR = 0.26; 95% CI = 0.05‐1.31), or cardiac hospitalization (HR = 0.79; 95% CI = 0.57‐1.11) between strategies. Preventive ablation was associated with improved SF‐36 physical component (mean difference = 2.81; 95% CI‐0.53‐5.10; P = .02), but not the mental component (mean difference = 1.30; 95% CI = ‐2.06‐4.66). Conclusion: Among patients with post‐infarct cardiomyopathy and VT, preventive catheter ablation at the time of ICD implantation is associated with a significant reduction of appropriate ICD therapy and sustained VT, and improvement in the physical component of quality‐of‐life, but no reduction in mortality. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 44:Issue 1(2021)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 44:Issue 1(2021)
- Issue Display:
- Volume 44, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2021-0044-0001-0000
- Page Start:
- 171
- Page End:
- 175
- Publication Date:
- 2020-11-13
- Subjects:
- cardiomyopathy -- catheter ablation -- implantable cardioverter defibrillators -- meta‐analysis -- myocardial infarction -- shocks -- ventricular tachyarrhythmias
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.14111 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21905.xml