- Effective mitigation of cross-contamination in classroom conditioned by intermittent air jet cooling with use of portable air cleaners
- Authors:
- Karam, Jennifer
Katramiz, Elvire
Ghali, Kamel
Ghaddar, Nesreen - Abstract:
- Abstract: This work investigated the effect of using portable air cleaners (PACs) in a classroom ventilated by an intermittent air jet system (IAJS) for reducing the risk of cross-contamination. The classroom had two student groups separated by an aisle where the PACs were placed and operated continuously. A 3-D computational fluid dynamic (CFD) model was developed and validated experimentally to predict the complex transient flow field. The spread of contaminants from one group to another ( scenario 1 ) and from one row to another within one group ( scenario 2 ) was evaluated in terms of reaching concentration levels similar to the case implementing the 2-m distancing between students. Two indicators were used; the intake fraction index ( iF ) and an exposure reduction index (ER ) that compared the proposed system to a reference case when the PAC is not used ("No-PAC"). It was found that a PAC flowrate of 350 m 3 /h was able to fulfill the aforementioned criteria for typical IAJS flow rate of 294 l/s and a period of 4.5 min. The proposed system reduced the exposure by 67% for the students sitting in the same group of the infected student and by 87% for the students sitting in the neighboring group compared to the "No-PAC " case. The maximum exposure level of IJAS-PAC system was lower than that obtained with seating distance of 2 m. Furthermore, it was found that operating the PAC at 350 m 3 /h resulted in 3% increase of the energy compared to operation of the IAJS alone.Abstract: This work investigated the effect of using portable air cleaners (PACs) in a classroom ventilated by an intermittent air jet system (IAJS) for reducing the risk of cross-contamination. The classroom had two student groups separated by an aisle where the PACs were placed and operated continuously. A 3-D computational fluid dynamic (CFD) model was developed and validated experimentally to predict the complex transient flow field. The spread of contaminants from one group to another ( scenario 1 ) and from one row to another within one group ( scenario 2 ) was evaluated in terms of reaching concentration levels similar to the case implementing the 2-m distancing between students. Two indicators were used; the intake fraction index ( iF ) and an exposure reduction index (ER ) that compared the proposed system to a reference case when the PAC is not used ("No-PAC"). It was found that a PAC flowrate of 350 m 3 /h was able to fulfill the aforementioned criteria for typical IAJS flow rate of 294 l/s and a period of 4.5 min. The proposed system reduced the exposure by 67% for the students sitting in the same group of the infected student and by 87% for the students sitting in the neighboring group compared to the "No-PAC " case. The maximum exposure level of IJAS-PAC system was lower than that obtained with seating distance of 2 m. Furthermore, it was found that operating the PAC at 350 m 3 /h resulted in 3% increase of the energy compared to operation of the IAJS alone. Graphical abstract: Image 1 Highlights: Portable air cleaners (PACs) are used in a classroom with an intermittent air jet system. A CFD model was developed and validated to assess the indoor contaminants' dispersion. The contaminants' concentration were lower than those obtained with the 2 m distancing. PACs at 350 m 3 /h reduced cross-contamination by 67%–87% compared to no PAC case. … (more)
- Is Part Of:
- Building and environment. Volume 219(2022)
- Journal:
- Building and environment
- Issue:
- Volume 219(2022)
- Issue Display:
- Volume 219, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 219
- Issue:
- 2022
- Issue Sort Value:
- 2022-0219-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-07-01
- Subjects:
- Intermittent air jet system -- Portable air cleaners -- Cross-contamination -- Air quality in classroom
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2022.109220 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21913.xml