Characterization and suppression of stripe artifact in velocity‐selective magnetization‐prepared unenhanced MR angiography. Issue 5 (13th March 2018)
- Record Type:
- Journal Article
- Title:
- Characterization and suppression of stripe artifact in velocity‐selective magnetization‐prepared unenhanced MR angiography. Issue 5 (13th March 2018)
- Main Title:
- Characterization and suppression of stripe artifact in velocity‐selective magnetization‐prepared unenhanced MR angiography
- Authors:
- Shin, Taehoon
Qin, Qin - Abstract:
- Abstract : Purpose: To characterize and suppress stripe artifact associated with velocity‐selective (VS) magnetization for unenhanced MRA. Methods: Extended phase graph formalism was used to show that the stripe artifact contains multiples of the fundamental frequency that is determined by the area of unipolar VS gradient. Four VS preparation pulses whose excitation profiles are spatially shifted by quarter the fundamental period of the stripes, were applied alternately. For further suppression of the artifact, k‐space data at kz = 0 were averaged over the 4 VS preparations. The proposed schemes were tested in a chicken breast phantom and healthy human subjects. Results: When the standard VS preparation scheme was used, stripe artifact was shown in all the reconstructed images and appeared as artifactual peaks in k‐space that corresponded to the first and second order harmonics of the fundamental frequency. Alternate application of the 4 phase‐shifted VS preparation pulses suppressed the stripes, but not completely, as evidenced by residual erroneous peaks in k‐space. After the k‐space averaging, the stripe artifact was nearly eliminated. Conclusion: Stripe artifact in VS‐MRA consists of multiples of the fundamental frequency and can be effectively suppressed through alternate application of phase‐shifted VS preparations along with k‐space averaging.
- Is Part Of:
- Magnetic resonance in medicine. Volume 80:Issue 5(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 80:Issue 5(2018)
- Issue Display:
- Volume 80, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 80
- Issue:
- 5
- Issue Sort Value:
- 2018-0080-0005-0000
- Page Start:
- 1997
- Page End:
- 2005
- Publication Date:
- 2018-03-13
- Subjects:
- non‐contrast‐enhanced MR angiography -- stripe artifact -- velocity‐selective magnetization preparation
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27160 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21908.xml