Reliability of oscillometric central hemodynamic responses to an orthostatic challenge. Issue 2 (August 2015)
- Record Type:
- Journal Article
- Title:
- Reliability of oscillometric central hemodynamic responses to an orthostatic challenge. Issue 2 (August 2015)
- Main Title:
- Reliability of oscillometric central hemodynamic responses to an orthostatic challenge
- Authors:
- Stoner, Lee
Bonner, Chantel
Credeur, Daniel
Lambrick, Danielle
Faulkner, James
Wadsworth, Daniel
Williams, Michelle A. - Abstract:
- Abstract: Background: Monitoring central hemodynamic responses to an orthostatic challenge may provide important insight into autonomic nervous system function. Oscillometric pulse wave analysis devices have recently emerged, presenting clinically viable options for investigating central hemodynamic properties. The purpose of the current study was to determine whether oscillometric pulse wave analysis can be used to reliably (between-day) assess central blood pressure and central pressure augmentation (augmentation index) responses to a 5 min orthostatic challenge (modified tilt-table). Methods: Twenty healthy adults (26.4 y (SD 5.2), 55% F, 24.7 kg/m 2 (SD 3.8)) were tested on 3 different mornings in the fasted state, separated by a maximum of 7 days. Central hemodynamic variables were assessed on the left arm using an oscillometric device. Results: Repeated measures analysis of variance indicated a significant main effect of the modified tilt-table for all central hemodynamic variables ( P < 0.001). In response to the tilt, central diastolic pressure increased by 4.5 mmHg (CI: 2.6, 6.4), central systolic blood pressure increased by 2.3 (CI: 4.4, 0.16) mmHg, and augmentation index decreased by an absolute – 5.3%, (CI: −2.7, −7.9%). The intra-class correlation coefficient values for central diastolic pressure (0.83–0.86), central systolic blood pressure (0.80–0.87) and AIx (0.79–0.82) were above the 0.75 criterion in both the supine and tilted positions, indicatingAbstract: Background: Monitoring central hemodynamic responses to an orthostatic challenge may provide important insight into autonomic nervous system function. Oscillometric pulse wave analysis devices have recently emerged, presenting clinically viable options for investigating central hemodynamic properties. The purpose of the current study was to determine whether oscillometric pulse wave analysis can be used to reliably (between-day) assess central blood pressure and central pressure augmentation (augmentation index) responses to a 5 min orthostatic challenge (modified tilt-table). Methods: Twenty healthy adults (26.4 y (SD 5.2), 55% F, 24.7 kg/m 2 (SD 3.8)) were tested on 3 different mornings in the fasted state, separated by a maximum of 7 days. Central hemodynamic variables were assessed on the left arm using an oscillometric device. Results: Repeated measures analysis of variance indicated a significant main effect of the modified tilt-table for all central hemodynamic variables ( P < 0.001). In response to the tilt, central diastolic pressure increased by 4.5 mmHg (CI: 2.6, 6.4), central systolic blood pressure increased by 2.3 (CI: 4.4, 0.16) mmHg, and augmentation index decreased by an absolute – 5.3%, (CI: −2.7, −7.9%). The intra-class correlation coefficient values for central diastolic pressure (0.83–0.86), central systolic blood pressure (0.80–0.87) and AIx (0.79–0.82) were above the 0.75 criterion in both the supine and tilted positions, indicating excellent between-day reliability. Conclusion: Central hemodynamic responses to an orthostatic challenge can be assessed with acceptable between-day reliability using oscillometric pulse wave analysis. Highlights: Autonomic nervous system function may be assessed using an orthostatic challenge. Central hemodynamics can be simply assessed using oscillometric pulse wave analysis. Oscillometric pulse wave analysis reliably assesses orthostatic challenge responses. … (more)
- Is Part Of:
- Atherosclerosis. Volume 241:Issue 2(2015)
- Journal:
- Atherosclerosis
- Issue:
- Volume 241:Issue 2(2015)
- Issue Display:
- Volume 241, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 241
- Issue:
- 2
- Issue Sort Value:
- 2015-0241-0002-0000
- Page Start:
- 761
- Page End:
- 765
- Publication Date:
- 2015-08
- Subjects:
- Pulse wave analysis -- Orthostatic challenge -- Central blood pressure -- Arterial wave reflection -- Augmentation index
Arteriosclerosis -- Periodicals
Electronic journals
616.136 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219150 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219150 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.atherosclerosis.2015.06.041 ↗
- Languages:
- English
- ISSNs:
- 0021-9150
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1765.874000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21863.xml