Analysis of cavopulmonary and cardiac flow characteristics in fontan Patients: Comparison with healthy volunteers. Issue 6 (11th January 2019)
- Record Type:
- Journal Article
- Title:
- Analysis of cavopulmonary and cardiac flow characteristics in fontan Patients: Comparison with healthy volunteers. Issue 6 (11th January 2019)
- Main Title:
- Analysis of cavopulmonary and cardiac flow characteristics in fontan Patients: Comparison with healthy volunteers
- Authors:
- Rutkowski, David R.
Barton, Gregory
François, Christopher J.
Bartlett, Heather L.
Anagnostopoulos, Petros V.
Roldán‐Alzate, Alejandro - Abstract:
- Abstract : Background: Characterizing the flow of the Fontan circuit, and correlating flow characteristics with the development of complications, is an important clinical challenge. Past work has analyzed the flow characteristics of Fontan circulation on a component‐by‐component basis. 4D flow MRI with radial projections allows for large volumetric coverage, and therefore can be used to analyze the flow through many codependent cardiovascular components in a single imaging session. Purpose: To describe flow characteristics across the entire Fontan circuit and to compare these with the flow characteristics in healthy volunteers. Study Type: Prospective. Subjects: Eleven single ventricle patients with a Fontan connection and 15 healthy controls. Sequence: Phase contrast with vastly undersampled isotropic projection reconstruction (PC‐VIPR) at a field strength of 3 T. Assessment: Cavopulmonary and ventricular flow distributions, blood flow kinetic energy, vorticities, efficiency indices, and other flow parameters were analyzed using Ensight and MatLab. Statistical Tests: The results were compared across Fontan subjects, between respiratory phases, and between Fontan subjects and healthy volunteers using a Student's t ‐test for unequal sample sizes and linear regression. Results: Cava‐specific pulmonary flow distributions of Fontan patients varied significantly between respiratory phases ( P < 0.05). Ventricular kinetic energy (KE) was significantly higher in Fontan patientsAbstract : Background: Characterizing the flow of the Fontan circuit, and correlating flow characteristics with the development of complications, is an important clinical challenge. Past work has analyzed the flow characteristics of Fontan circulation on a component‐by‐component basis. 4D flow MRI with radial projections allows for large volumetric coverage, and therefore can be used to analyze the flow through many codependent cardiovascular components in a single imaging session. Purpose: To describe flow characteristics across the entire Fontan circuit and to compare these with the flow characteristics in healthy volunteers. Study Type: Prospective. Subjects: Eleven single ventricle patients with a Fontan connection and 15 healthy controls. Sequence: Phase contrast with vastly undersampled isotropic projection reconstruction (PC‐VIPR) at a field strength of 3 T. Assessment: Cavopulmonary and ventricular flow distributions, blood flow kinetic energy, vorticities, efficiency indices, and other flow parameters were analyzed using Ensight and MatLab. Statistical Tests: The results were compared across Fontan subjects, between respiratory phases, and between Fontan subjects and healthy volunteers using a Student's t ‐test for unequal sample sizes and linear regression. Results: Cava‐specific pulmonary flow distributions of Fontan patients varied significantly between respiratory phases ( P < 0.05). Ventricular kinetic energy (KE) was significantly higher in Fontan patients than it was in healthy controls, leading to a lower cardiac efficiency metric in the Fontan group. A significant diastolic KE time‐shift was also observed in the Fontan patient group. Peak diastolic KE was significantly higher in the single ventricle of patients with right ventricle morphology than it was in left ventricle morphology patients. Data Conclusion: Radial 4D flow MRI can be used for comprehensive analysis of single ventricle Fontan flow characteristics. Level of Evidence : 2 Technical Efficacy : Stage 2 J. Magn. Reson. Imaging 2019. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 49:Issue 6(2019)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 49:Issue 6(2019)
- Issue Display:
- Volume 49, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 49
- Issue:
- 6
- Issue Sort Value:
- 2019-0049-0006-0000
- Page Start:
- 1786
- Page End:
- 1799
- Publication Date:
- 2019-01-11
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.26583 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21826.xml