Diffusion‐PEPTIDE: Distortion‐ and blurring‐free diffusion imaging with self‐navigated motion‐correction and relaxometry capabilities. Issue 5 (12th December 2020)
- Record Type:
- Journal Article
- Title:
- Diffusion‐PEPTIDE: Distortion‐ and blurring‐free diffusion imaging with self‐navigated motion‐correction and relaxometry capabilities. Issue 5 (12th December 2020)
- Main Title:
- Diffusion‐PEPTIDE: Distortion‐ and blurring‐free diffusion imaging with self‐navigated motion‐correction and relaxometry capabilities
- Authors:
- Fair, Merlin J.
Liao, Congyu
Manhard, Mary Kate
Setsompop, Kawin - Abstract:
- Abstract : Purpose: To implement the time‐resolved relaxometry PEPTIDE technique into a diffusion acquisition to provide self‐navigated, distortion‐ and blurring‐free diffusion imaging that is robust to motion, while simultaneously providing T2 and T 2 ∗ mapping. Theory and Methods: The PEPTIDE readout was implemented into a spin‐echo diffusion acquisition, enabling reconstruction of a time‐series of T2 ‐ and T 2 ∗ ‐weighted images, free from conventional echo planar imaging (EPI) distortion and blurring, for each diffusion‐encoding. Robustness of PEPTIDE to motion and shot‐to‐shot phase variation was examined through a deliberate motion‐corrupted diffusion experiment. Two diffusion‐relaxometry in vivo brain protocols were also examined: (1)1 × 1 × 3 mm 3 across 32 diffusion directions in 20 min, (2)1.5 × 1.5 × 3.0 mm 3 across 6 diffusion‐weighted images in 3.4 min. T2, T 2 ∗, and diffusion parameter maps were calculated from these data. As initial exploration of the rich diffusion‐relaxometry data content for use in multi‐compartment modeling, PEPTIDE data were acquired of a gadolinium‐doped asparagus phantom. These datasets contained two compartments with different relaxation parameters and different diffusion orientation properties, and T2 relaxation variations across these diffusion directions were explored. Results: Diffusion‐PEPTIDE showed the capability to provide high quality diffusion images and T2 and T 2 ∗ maps from both protocols. The reconstructions wereAbstract : Purpose: To implement the time‐resolved relaxometry PEPTIDE technique into a diffusion acquisition to provide self‐navigated, distortion‐ and blurring‐free diffusion imaging that is robust to motion, while simultaneously providing T2 and T 2 ∗ mapping. Theory and Methods: The PEPTIDE readout was implemented into a spin‐echo diffusion acquisition, enabling reconstruction of a time‐series of T2 ‐ and T 2 ∗ ‐weighted images, free from conventional echo planar imaging (EPI) distortion and blurring, for each diffusion‐encoding. Robustness of PEPTIDE to motion and shot‐to‐shot phase variation was examined through a deliberate motion‐corrupted diffusion experiment. Two diffusion‐relaxometry in vivo brain protocols were also examined: (1)1 × 1 × 3 mm 3 across 32 diffusion directions in 20 min, (2)1.5 × 1.5 × 3.0 mm 3 across 6 diffusion‐weighted images in 3.4 min. T2, T 2 ∗, and diffusion parameter maps were calculated from these data. As initial exploration of the rich diffusion‐relaxometry data content for use in multi‐compartment modeling, PEPTIDE data were acquired of a gadolinium‐doped asparagus phantom. These datasets contained two compartments with different relaxation parameters and different diffusion orientation properties, and T2 relaxation variations across these diffusion directions were explored. Results: Diffusion‐PEPTIDE showed the capability to provide high quality diffusion images and T2 and T 2 ∗ maps from both protocols. The reconstructions were distortion‐free, avoided potential resolution losses exceeding 100% in equivalent EPI acquisitions, and showed tolerance to nearly 30° of rotational motion. Expected variation in T2 values as a function of diffusion direction was observed in the two‐compartment asparagus phantom ( P < .01), demonstrating potential to explore diffusion‐PEPTIDE data for multi‐compartment modeling. Conclusions: Diffusion‐PEPTIDE provides highly robust diffusion and relaxometry data and offers potential for future applications in diffusion‐relaxometry multi‐compartment modeling. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 5(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 5(2021)
- Issue Display:
- Volume 85, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2021-0085-0005-0000
- Page Start:
- 2417
- Page End:
- 2433
- Publication Date:
- 2020-12-12
- Subjects:
- blurring‐free -- diffusion imaging -- diffusion‐relaxometry -- distortion‐free -- motion‐robust -- multi‐shot
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28579 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21832.xml