Improved reproducibility of diffusion MRI of the human brain with a four‐way blip‐up and down phase‐encoding acquisition approach. Issue 5 (16th December 2020)
- Record Type:
- Journal Article
- Title:
- Improved reproducibility of diffusion MRI of the human brain with a four‐way blip‐up and down phase‐encoding acquisition approach. Issue 5 (16th December 2020)
- Main Title:
- Improved reproducibility of diffusion MRI of the human brain with a four‐way blip‐up and down phase‐encoding acquisition approach
- Authors:
- Irfanoglu, M. Okan
Sadeghi, Neda
Sarlls, Joelle
Pierpaoli, Carlo - Abstract:
- Abstract : Purpose: To assess the effects of blip‐up and ‐down echo planar imaging (EPI) acquisition designs, with different choices of phase‐encoding directions (PEDs) on the reproducibility of diffusion MRI (dMRI)‐derived metrics in the human brain. Methods: Diffusion MRI data in seven subjects were acquired five times, each with five different protocols. The base design included 64 diffusion directions acquired with anterior‐posterior (AP) PED, the first and second protocols added reverse phase‐encoded b = 0 s / mm 2 posterior‐anterior (PA) PED images. The third one included 32 directions all with PED acquisitions with opposite polarity (AP and PA). The fourth protocol, also with 32 unique directions used four PEDs (AP, PA, right‐left (RL), and left‐right (LR)). The scan time was virtually identical for all protocols. The variability of diffusion MRI metrics for each subject and each protocol was computed across the different sessions. Results: The highest reproducibility for all dMRI metrics was obtained with protocol four (AP/PA‐RL/LR, ie, four‐way PED). Protocols that used only b = 0 s / mm 2 for distortion correction, which are the most widely used designs, had the lowest reproducibility. Conclusions: An acquisition design with four PEDs, including all DWIs in addition to b = 0 s / mm 2 images should be used to achieve high reproducibility in diffusion MRI studies. Abstract : Click here for author‐reader discussions
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 5(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 5(2021)
- Issue Display:
- Volume 85, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2021-0085-0005-0000
- Page Start:
- 2696
- Page End:
- 2708
- Publication Date:
- 2020-12-16
- Subjects:
- artifacts -- diffusion MRI -- distortion correction -- EPI -- reproducibility
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28624 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21832.xml