Computer‐assisted beam modeling for particle therapy. Issue 2 (25th December 2020)
- Record Type:
- Journal Article
- Title:
- Computer‐assisted beam modeling for particle therapy. Issue 2 (25th December 2020)
- Main Title:
- Computer‐assisted beam modeling for particle therapy
- Authors:
- Fuchs, Hermann
Elia, Alessio
Resch, Andreas F.
Kuess, Peter
Lühr, Armin
Vidal, Marie
Grevillot, Loïc
Georg, Dietmar - Abstract:
- Abstract : Purpose: To develop a computer‐driven and thus less user‐dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. Methods: In a first step, experimental measurements were performed for proton and carbon ion energies in the available energy ranges. Data included depth dose profiles measured in water and spot sizes in air at various isocenter distances. Using an automated regularization‐based optimization process (AUTO‐BEAM), GATE/Geant4 beam models of the respective beam lines were generated. These were obtained sequentially by using least square weighting functions with and without regularization, to iteratively tune the beam parameters energy, energy spread, beam sigma, divergence, and emittance until a user‐defined agreement was reached. Based on the parameter tuning for a set of energies, a beam model was semi‐automatically generated. The resulting beam models were validated for all centers comparing to independent measurements of laterally integrated depth dose curves and spot sizes in air. For one representative center, three‐dimensional dose cubes were measured and compared to simulations. The method was applied on one research as well as four different clinical beam lines for proton and carbon ions of three different particle therapy centers using synchrotron or cyclotron accelerator systems: (a) MedAustron ion therapy center, (b) University ProtonAbstract : Purpose: To develop a computer‐driven and thus less user‐dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. Methods: In a first step, experimental measurements were performed for proton and carbon ion energies in the available energy ranges. Data included depth dose profiles measured in water and spot sizes in air at various isocenter distances. Using an automated regularization‐based optimization process (AUTO‐BEAM), GATE/Geant4 beam models of the respective beam lines were generated. These were obtained sequentially by using least square weighting functions with and without regularization, to iteratively tune the beam parameters energy, energy spread, beam sigma, divergence, and emittance until a user‐defined agreement was reached. Based on the parameter tuning for a set of energies, a beam model was semi‐automatically generated. The resulting beam models were validated for all centers comparing to independent measurements of laterally integrated depth dose curves and spot sizes in air. For one representative center, three‐dimensional dose cubes were measured and compared to simulations. The method was applied on one research as well as four different clinical beam lines for proton and carbon ions of three different particle therapy centers using synchrotron or cyclotron accelerator systems: (a) MedAustron ion therapy center, (b) University Proton Therapy Dresden, and (c) Center Antoine Lacassagne Nice. Results: Particle beam ranges in the MC beam models agreed on average within 0.2 mm compared to measurements for all energies and beam lines. Spot sizes in air (full‐width at half maximum) at all positions differed by less than 0.4% from the measurements. Dose calculation with the beam model for the clinical beam line at MedAustron agreed better than 1.7% in absolute dose for a representative clinical case treated with protons. For protons, beam model generation, including geometry creation, data conversion, and validation, was possible within three working days. The number of iterations required for the optimization process to converge, was found to be similar for all beam line geometries and particle types. Conclusion: The presented method was demonstrated to work independently of the beam optics behavior of the different beam lines, particle types, and geometries. Furthermore, it is suitable for non‐expert users and requires only limited user interaction. Beam model validation for different beam lines based on different beam delivery systems, showed good agreement. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 2(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 2(2021)
- Issue Display:
- Volume 48, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 2
- Issue Sort Value:
- 2021-0048-0002-0000
- Page Start:
- 841
- Page End:
- 851
- Publication Date:
- 2020-12-25
- Subjects:
- beam modeling -- carbon ions -- Monte Carlo -- particle therapy -- proton therapy -- optimization
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14647 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 21825.xml