Intersegmenter Variability in High‐Speed Laryngoscopy‐Based Glottal Area Waveform Measures. (16th December 2019)
- Record Type:
- Journal Article
- Title:
- Intersegmenter Variability in High‐Speed Laryngoscopy‐Based Glottal Area Waveform Measures. (16th December 2019)
- Main Title:
- Intersegmenter Variability in High‐Speed Laryngoscopy‐Based Glottal Area Waveform Measures
- Authors:
- Maryn, Youri
Verguts, Monique
Demarsin, Hannelore
van Dinther, Joost
Gomez, Pablo
Schlegel, Patrick
Döllinger, Michael - Abstract:
- Abstract : Objectives/Hypothesis: High‐speed videoendoscopy (HSV) has potential to objectively quantify vibratory vocal fold characteristics during phonation. Glottal Analysis Tools (GAT) version 2018, developed in Erlangen, Germany, is software for determining various glottal area waveform (GAW) quantities. Before having GAT analyze HSV videos, segmenters have to define glottis manually across videos in a semiautomatic segmentation protocol. Such interventions are hypothesized to induce variability of subsequent GAW measure computation across segmenters and may attenuate GAT measures' reliability to a certain point. This study explored intersegmenter variability in GAT's GAW measures based on semiautomatic image processing. Study Design: Cohort study of rater reliability. Methods: In total, 20 HSV videos from normophonic and dysphonic subjects with various laryngeal disorders were selected for this study and segmented by three trained segmenters. They separately segmented glottis areas in the same frame sets of the videos. Upon analysis of GAW, GAT offers 46 measures related to topologic GAW dynamic characteristics, GAW periodicity and perturbation characteristics, and GAW harmonic components. To address GAT's reliability, intersegmenter‐based variability in these measures was examined with intraclass correlation coefficient (ICC). Results: In general, ICC behavior of the 46 GAW measures across three raters was highly acceptable. ICC of one parameter was moderateAbstract : Objectives/Hypothesis: High‐speed videoendoscopy (HSV) has potential to objectively quantify vibratory vocal fold characteristics during phonation. Glottal Analysis Tools (GAT) version 2018, developed in Erlangen, Germany, is software for determining various glottal area waveform (GAW) quantities. Before having GAT analyze HSV videos, segmenters have to define glottis manually across videos in a semiautomatic segmentation protocol. Such interventions are hypothesized to induce variability of subsequent GAW measure computation across segmenters and may attenuate GAT measures' reliability to a certain point. This study explored intersegmenter variability in GAT's GAW measures based on semiautomatic image processing. Study Design: Cohort study of rater reliability. Methods: In total, 20 HSV videos from normophonic and dysphonic subjects with various laryngeal disorders were selected for this study and segmented by three trained segmenters. They separately segmented glottis areas in the same frame sets of the videos. Upon analysis of GAW, GAT offers 46 measures related to topologic GAW dynamic characteristics, GAW periodicity and perturbation characteristics, and GAW harmonic components. To address GAT's reliability, intersegmenter‐based variability in these measures was examined with intraclass correlation coefficient (ICC). Results: In general, ICC behavior of the 46 GAW measures across three raters was highly acceptable. ICC of one parameter was moderate (0.5 < ICC < 0.75), good for seven parameters (0.75 < ICC < 0.9), and excellent for 38 parameters (0.9 < ICC). Conclusions: Overall, high ICC values confirm clinical applicability of GAT for objective and quantitative assessment of HSV. Small intersegmenter differences with actual small parameter differences suggest that manual or semiautomatic segmentation in GAT does not noticeably influence clinical assessment outcome. To guarantee the software's performance, we suggest segmentation training before clinical application. Level of Evidence: 2b Laryngoscope, 130:E654–E661, 2020 … (more)
- Is Part Of:
- Laryngoscope. Volume 130:Number 11(2020)
- Journal:
- Laryngoscope
- Issue:
- Volume 130:Number 11(2020)
- Issue Display:
- Volume 130, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 11
- Issue Sort Value:
- 2020-0130-0011-0000
- Page Start:
- E654
- Page End:
- E661
- Publication Date:
- 2019-12-16
- Subjects:
- High‐speed videoendoscopy -- glottis segmentation -- reliability -- quantitative parameters
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.28475 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: